English
Language : 

TL94-025-010 Datasheet, PDF (1/2 Pages) DB Lectro Inc – CHASSIS MOUNT TRANSFORMER
DB LECTRO Inc.
CHASSIS MOUNT
TRANSFORMER
TL94 Series
• Power – 25VA to 175VA
• Dielectric Strength – 4000Vrms
• Primary – Dual primary (115V/230V 50/60Hz)
• Secondary – Series or parallel
• Terminal – Solder lug / quick-connect type
terminal
• Insulation Class – Class F (155°C)
• Flammability Rating – UL94V-0 (bobbin)
• Safety Approvals – UL506, CSA C22.2
#66 , TUV / EN60950 & CE
C
A
E
D
#6
#12
#5
#11
B
#2
#8
#1
#7
C
A
E
D
#6
#12
#5
#11
B
#4
#3
#10
#9
#2
#8
#1
#7
F
#6
#12
F
#6
#12
115V
50/60 Hz
SEC 2
115V
50/60 Hz
SEC 2
#5
#11
#2
#8
G
#5
#11
#2
#8
G
115V
50/60 Hz
SEC 1
115V
50/60 Hz
SEC 1
#1
#7
#1
#7
H
MOUNTING STYLE A
MOUNTING STYLE B
Product
Series
25 (VA)
43 (VA)
80 (VA)
130 (VA)
175 (VA)
Dimensions (mm)
Mtg. Mtg.
A
B
C
D
E
F
G
H Style Screw
49.8 60.0 47.6 28.6 7.9 4.75 60.3
--
A
#6
57.2 69.2 52.3 28.6 7.9 4.75 71.4
--
A
#6
63.5 76.2 60.3 35.5 7.9 4.75 50.8 55.5
B
#6
71.5 85.8 73.0 41.5 9.5 6.35 57.2 63.5
B
#8
80.0 96.0 79.0 41.5 9.5 6.35 64.0 64.0
B
#8
Note:
1) The Mtg. Screw size is the maximum allowable screw size.
2) Unused terminals are omitted for standard parts. Unused terminals can be provided on request.
3) For 25VA & 43VA series, maximum 10 terminals are available.
4) For 80VA to 175VA series, maximum 12 terminals are available.