English
Language : 

SM1A100KC Datasheet, PDF (1/2 Pages) DB Lectro Inc – ALUMINIUM ELECTROLYTIC CAPACITOR
RoHS Compliant ALUMINIUM ELECTROLYTIC CAPACITOR
FEATURES
◆ Miniaturized low profile with 9mm to 25mm height
◆ Load life of 2000 hours at 85°C
OUTLINE
SM Series
SPECIFICATIONS
Items
Capacitance Tolerance
(120Hz, 25°C)
Rated Working Voltage Range
Operation Temperature
Leakage Current (25°C)
Surge Voltage (25°C)
Dissipation Factor (120Hz, 25°C)
Temperature Characteristics
Load Test
Shelf Test
mm
D 5 6.3 8 10 13 16 18
F 2.0 2.5 3.5
5.0
7.5
d
0.5
0.6
0.8
Characteristics
± 20% (M)
6.3 ~ 250Vdc
350 ~ 450Vdc
-40°C ~ +85°C
-25°C ~ +85°C
(After 2 minutes applying the DC working voltage)
(After 1 minute applying the DC working voltage)
I ≤ 0.01CV or 3 (u A)
I ≤ 0.04CV + 100 (u A)
◆ I : Leakage Current (u A)
◆ C : Rated Capacitance (u F)
◆ V : Working Voltage (V)
W.V.
6.3 10 16 25 35 50 160 200 250 350 400 450
S.V.
8 13 20 32 44 63 200 250 300 400 450 500
W.V.
6.3 10 16 25 35 50 160 200 250 350 400 450
tan δ
0.28 0.24 0.20 0.16 0.14 0.12 0.15 0.15 0.15 0.20 0.24 0.24
◆ For capacitance exceeding 1000 u F, add 0.02 per increment of 1000 u F
W.V.
6.3 10 16 25 35 50 160 200 250 350 400 450
- 25°C / + 25°C 5 4 3 2 2 2 3 3 3 6 6 6
- 40°C / + 25°C 12 10 8 5 4 3 6 6 6 - - -
◆ Impedance ratio at 120Hz
After 2000 hours application of WV at +85°C, the capacitor shall meet the following limits:
(1000 hours for 8φ and smaller)
Capacitance Change ≤ ± 20% of initial value
tan δ
≤ 200% of initial specified value
Leakage Current
≤ initial specified value
After 1000 hours, no voltage applied at +85°C, the capacitor shall meet the following limits:
Capacitance Change ≤ ± 20% of initial value
tan δ
≤ 200% of initial specified value
Leakage Current
≤ 200% of initial specified value
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com