NT90T Datasheet, PDF (1/4 Pages) DB Lectro Inc – Small size, light weight. Low coil power consumption, heavy contact load. Strong anti-shock and anti-vibration, high reliability, long life. | |||
|
32.4Ã27.5Ã28.0
NT90T (T91)
NT90T (T91)
ï¼NT90T2ï¼
32.4Ã27.5Ã20
CH050401â2000
E160644 E233737
Patent No. 99312549.2
E9930952E01
R2033977.06
Features
Small size, light weight. Low coil power consumption, heavy contact load. Strong anti-shock and anti-vibration, high
reliability, long life.
Suitable for automobile, machine, electronic equipment, air conditioner and household appliance applications.
PC board mounting and direct insert mounting available.
Ordering Information
NT90T H L A S DC12V C B 0.9
1
2345 6
789
1 Part numberï¼NT90TãNT90T2
2 Loadï¼H:30Aï¼N:40A
3 Highï¼NIL: Standardï¼L: Low profile type
4 Contact arrangementï¼A:1Aï¼B:1Bï¼C:1C
5 Enclosureï¼S: Sealed typeï¼D: Dust coverï¼
E: Coveredï¼O: Open type
6 Coil rated Voltage(V)ï¼AC:12,24,110,120,220
DC:3,5,6,9,12,15,18,24,48,110
7 Contact materialï¼C: Ag CdOï¼S: Ag SnO2
8 Resist heat classï¼B:130â F:155â
9 Coil power consumptionï¼0.6:0.6Wï¼0.9:0.9W
NIL:2VA
Contact Data
Contact Arrangement
Contact Material
Contact Rating (resistive)
Max. Switching Power
Max. Switching Voltage
Contact Resistance or Voltage drop
Operation Electrical
life
Mechanical
Coil Parameter
AC Coil Parameter
DASH
NUMBERS
012AC
024AC
110AC
120AC
220AC
RATED VOLTAGE
VAC
RATED
12
24
110
120
220
Max
15.6
31.2
143
156
286
1A SPSTBNO f1B SPSTNC f1C SPDT(B-M)
Ag CdO Ag SnO2 Ag SnO2 In2O3
NOï¼30A/240VAC,14VDCï¼NCï¼20A/240VAC ;30A/14VDC
NOï¼40A/250VAC,30VDCï¼NCï¼30A/250VAC,30VDC (0.9W)
Motor loadï¼2HP 250VAC ï¼1.5HP 250V
Lamp loadï¼TV-5
1100W 7200VA
110VDC 250VAC
Max. Switching Current:40A
á 30m
Item 3.12 of IEC255-7
105
Item 3.30 of IEC255-7
107
Item 3.31 of IEC255-7
COIL
RESISTANCE
±10%
27
120
2360
3040
13490
PICK UP
VOLTAGE
VAC(max)
(75%of
rated
voltage)
9.0
18.0
82.5
90.0
165.0
RELEASE
VOLTAGE
VAC(min)
(30%of
rated
voltage)
3.6
7.2
33.0
36.0
66.0
COIL
POWER
2VA
Operate
Time
ms
_
Release
Time
ms
_
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
www.dblectro.com
|
▷ |