English
Language : 

N932 Datasheet, PDF (1/2 Pages) DB Lectro Inc – Switching capacity up to 15A
DB LECTRO INC
N932
31×23
Features
n Switching capacity up to 15A.
n Suitable for automation system and auxiliary automobile etc.
Contact Data
Contact Arrangement
Contact Material
Contact Rating (resistive)
Max. Switching Power
Max. Switching Voltage
Contact Resistance or Voltage drop
Operation Electrical
life
Mechanical
Coil Parameter
1C
Au AgNi
15A/14VDC
210W
15VDC
50mΩ Max.
105
107
Max. Switching Current:15A
Item 3.12 of IEC255-7
Item 3.30 of IEC255-7
Item 3.31 of IEC255-7
Coil voltage
VDC
Rated Max.
Coil resistance
Ω±10%
Pickup
voltage
VDC(max)
(67%of rated
voltage )
Release
voltage
VDC(min)
(10% of rated
voltage)
Coil power
consumption
W
Operate
Time
ms
Max.
Release
Time
ms
Max.
12
15.6
120
8
1.2
1.2
10
8
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
Operation condition
Insulation Resistance1)
Dielectric Strength 1)
Between contacts
Between contact and coil
100MΩ min (at 500VDC)
50Hz 500V
50Hz 500V
Item 7 of IEC255-5
Item 6 of IEC255-5
Item 6 of IEC255-5
Shock resistance
Vibration resistance
100m/s 2
11ms
10~55Hz double amplitude 1.5mm
IEC68-2-27 Test Ea method 1
IEC68-2-6 Test Fc
Terminals strength
8N
IEC68-2-21 Test Ua2
Solderability
230 ºC±2 ºC 10±0.5s
IEC68-2-20 Test Ta method 1
Ambient Temperature
-40~125 ºC
Relative Humidity
85% (at 40 ºC)
IEC68-2-3Test Ca
Mass
31g
Note: 1). When testing, coil terminals shall be connect ,if coil transient suppression is installed in relay .
Qualification inspection:
Perform the qualification test as specified in the table IV of IEC255-19-1 and minimum sample size 24.
107