M1BS Datasheet, PDF (1/2 Pages) DB Lectro Inc – DIL Pitch Terminals High Sensitivity Relay
M1BS
20.0×9.8×11.0
E158859
Features
DIL Pitch Terminals .High Sensitivity g
Conforms to FCC Part 68 1.5kV Surge and Dielectric 1000VACg
Fully sealed (immersion clearable).
High Reliability bifurcated Contact.
Application for Telecommunication EquipmentfOffice Equipmentf Security Alarm Systemsf Measuring instrumentsf
Medical Monitoring EquipmentfAudio Visual Equipmentf Flight SimulatorfSensor Controlg
Contact Data
Contact Arrangement
2C
Contact Material
PdRu
Contact Rating (resistive) 2A/30VDC; 0.6A/125VAC
Max. Switching Power
60W 125VA
Min. Switching load 1mA/1V Reference Value
Max. Switching Voltage 220VDC 250VAC
Max. Switching Current:2A
Contact Resistance
Voltage drop
or
አ100m
Item 3.12 of IEC255-7
Operation Electrical 3y105 Ag Alloy 1y105
Item 3.30 of IEC255-7
life
Mechanical 108
Item 3.31 of IEC255-7
CAUTION:
Relays previously tested or used above 10mA resistive at 6VDC maximum or peak AC open circuit are not
recommended for subsequent use in low level applications.
Coil Parameter
Coil voltage
VDC
Rated Max.
3
4.2
5
7.0
6
8.4
9
12.3
12
17.4
24
34.0
48
64.9
3
4.9
5
8.1
6
9.7
9
14.5
12
19.4
24
38.9
48
77.8
Coil resistance
±10%
16
45
66
140
280
1070
3900
22.5
62.5
90
203
360
1440
5760
Pick up voltage
VDC(max)
(70% of rated
voltage )
2.1
3.5
4.2
6.3
8.4
16.8
33.6
2.1
3.5
4.2
6.3
8.4
16.8
33.6
release voltage
VDC(min)
(10% of rated
voltage)
0.3
0.5
0.6
0.9
1.2
2.4
4.8
0.3
0.5
0.6
0.9
1.2
2.4
4.8
Coil
power
W
0.56
0.56
0.55
0.58
0.52
0.54
0.59
0.4
0.4
0.4
0.4
0.4
0.4
0.4
Operate
Time
ms
3
3
Release
Time
ms
1.5
1.5
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
Qualification inspection:
Perform the qualification test as specified in the table
of IEC255-19-1 and minimum sample size 24.