English
Language : 

KAQV414 Datasheet, PDF (1/2 Pages) DB Lectro Inc – High Voltage, Photo Mos Relay
DB LECTRO Inc. High Voltage, Photo DEMos Relay KAQV414/414A
UL 1577/ UL 508 (File No.E108430), FI EN60950 (File No.FI13698)
Features
1. Normally Close, Single Pole Single Throw
2. Control 400VAC or DC Voltage
3. Switch 130mA Loads
4. LED control Current, 5mA
5. Low ON-Resistance
6. dv/dt, >500V/ms
7. Isolation Test Voltage, 3750VACrms
KAQV414
Unit : mm
TOLERANCE : ± 0.2mm
KAQV414A
Absolute Maximum Ratings
(Ta=25°C)
Emitter ( Input )
Reverse Voltage……………………………5.0V
Continuous Forward Current ……………50mA
Peak Forward Current ………………………1A
Power Dissipation ……………………100mW
Derate Linearly from 25°C …………1.3mW/°C
Detector ( Output )
Output Breakdown Voltage ……………±400V
Continuous Load Current ……………±130mA
Power Dissipation ……………………500mW
General Characteristics
Isolation Test Voltage……………3750VACrms
Isolation Resistance
Vio=500V, Ta=25°C ……………………•1010Ÿ
Total Power Dissipation ………………550mW
Derate Linearly from 25°C …………2.5mW/°C
Storage Temperature Range …-40°C to +125°C
Operating Temperature Range…-30°C to +85°C
Junction Temperature……………………100°C
Soldering Temperature,
2mm from case, 10 sec …………………260°C
Electro-optical Characteristics
Parameter
Emitter (Input)
Forward Voltage
Operation Input Current
Recovery Input Current
Detector (Output)
Output Breakdown Voltage
Output Off-State Leakage
I/O Capacitance
A
ON Resistance Connection B
C
Reverse (ON) Time
Operate (OFF) Time
Symbol
VF
IFOFF
IFON
VB
ITOFF
CISO
RON
TON
TOFF
Conditions
IF =10mA
VL =±20V, IL ”5uA
VL =±20V, IL =100mA, t =10mS
IB=50uA
VT =100V, IF =10mA
IF =0, f =1MHZ
IL =100mA, IF =10mA
IF =10mA, VL =±20V
t =10ms, IL =±100mA
Mos Relay Schematic and Wiring Diagrams
Type
Schematic
Output
configuration
Load
Connection
AC/DC
A
KAQV414
&
1a
DC
B
KAQV414A
DC
C
Unit : mm
TOLERANCE : ± 0.2mm
Operate/ Reverse time
Min.
Typ.
(Ta=25°C)
Max.
Unit
1.2
1.5
V
5
mA
0.2
mA
400
V
0.2
2
uA
6
pF
40
50
20
25
Ÿ
10
12.5
0.6
1.5
ms
0.3
1.0
ms
Wiring Diagrams