English
Language : 

JQX-14FC Datasheet, PDF (1/3 Pages) DB Lectro Inc – ELECTRONIC COMPONENTS
29×12.8×26
JQX-14FC1 & JQX-14FC2 JQX-14FC3
JQX-14FC1 & JQX-14FC2
JQX-14FC3
CH0050405—2000 E9930952E01
E160644
R2033977.01
Features
Heavy load, suitable for heavy power reverse.
Small size, suitable for high-density mounting.
Up to 5000VAC dielectric strength. Between open contacts of JQX-14FC3 3000VAC dielectric strength.
Contact gap of JQX-14FC3 :2y1.5mm=3mm.
Suitable for remote control TV set, copy machine, sales machine and air conditioner etc.
Ordering Information
JQX-14FC1 C S 10 DC12V 0.8 3.5
1
23 4
5
6
7
1 Part number:JQX-14FC1 JQX-14FC2 JQX-14FC3
2 Contact arrangement:A:1A;2A:2A;C:1C;2C:2C
3 Enclosure:S: Sealed type;Z: Dust cover
4 Contact Current:3A,5A,6A,8A,10A,16A,20A
5 Coil rated Voltage(V):DC:3,5,6,9,12,15,24
6 Coil power cunsumption:NIL:0.53W;0.8:0.8W;1.2:1.2W
7 Pole-distance:3.5:3.5mm;5:5.0mm
Contact Data
Contact Arrangement
Contact Material
Contact Rating (resistive)
Max. Switching Power
Max. Switching Voltage
Contact Resistance or Voltage drop
Operation life Electrical
Mechanical
Contact gap
Coil Parameter
1A SPSTNO f2A DPSTNO f1C SPDT(B-M) f2C DPDT(B-M)
Ag CdO Ag SnO2
1A:16A/220VAC,30VDC;
1C:10A,16A,20A/220VAC,30VDC;
10A/250VAC,14VDC(20A Application for 5mmPole-distance)
2A,2C:5A,8A/220VAC, 30VDC; JQX-14FC3 2A 8A/220VAC 2C 6A/220VAC
Motor load : 1HP 250VAC ; 1/2HP 125VAC
Lamp load : TV-5
300W 2200VA
110VDC 380VAC
Max. Switching Current:20A
አ50m
Item 3.12 of IEC255-7
105
Item 3.30 of IEC255-7
107 5y106 (JQX-14FC3
Item 3.31 of IEC255-7
2y1.5mm=3mm( for JQX-14FC3
Dash
numbers
003-530
005-530
006-530
009-530
012-530
024-530
Coil voltage
VDC
Rated
3
5
6
9
12
24
Max.
3.9
6.5
7.8
11.7
15.6
31.2
Coil
resistance
±10%
C1 C2
17
47
68
153
275
1100
Pickup
voltage
VDC(max)
(75%of rated
voltage )
2.25
3.75
4.50
6.75
9.00
18.0
release
voltage
VDC(min)
(10% of
rated
voltage)
0.3
0.5
0.6
0.9
1.2
2.4
Coil power
consumption
W
C1 C2
0.53
Operate
Time
ms
C1 C2
15
Release
Time
ms
C1 C2
10
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
www.dblectro.com