English
Language : 

JMX-94F Datasheet, PDF (1/2 Pages) DB Lectro Inc – Magnet latching relay Small size, light weight
JMX-94F
39×30×17.5
Features
Magnet latching relay.
Small size, light weight.
High sensitivity & reliability.
Well anti-shock and anti-vibration.
Heavy contact load.
CH0054070—2000
Ordering Information
JMX-94F A Z 60 DC12V
1
2 34
5
1 Part number:JMX-94F
2 Contact arrangement:A:1A;B:1B
3 Enclosure:S: Sealed type;Z: Dust cover
4 Contact Current:40:40A;60:60A;80:80A
5 Coil rated Voltage(V):DC: 9,12, 24
Contact Data
Contact Arrangement
Contact Material
Contact Rating(resistive)
Max. Switching Power
Max. Switching Voltage
Contact Resistance & Voltage drop
Operation life
Electrical
(Rated load)
Mechanical
(No load)
Coil Parameter
1A SPSTNO f1B SPSTNC
Ag Cd O
80A/250VAC 60A/250VAC
40A/250VAC
20000VA
15000VA
10000VA
300VAC
Max. Switching Current:80A
አ50m (at 1A/24VDC) Item 3.12 of IEC255-7
100mV (at rated load) Item 3.12 of IEC255-7
104
Item 3.30 of IEC255-7
106
Item 3.31 of IEC255-7
DASH
NUMBERS
COIL
RATED
VOLTAGE
VDC
COIL
RESISTANCE
±10%
SWITCHING
VOLTAGE
VDC
(50%-70% of
rated voltage)
PULSE
MAGNITUDE
ms
COIL
POWER
consumption
W
Operate
Time
ms
Reset
Time
ms
009-1000
9
81
4.5~6.3
012-1000
12
144
6.0~8.4
60
1
20
20
024-1000
24
576
12.0~16.8
CAUTION: 1.When latching relays are installed in equipment, the latch and reset coil should not be pulsed simultaneously.
coil should not be pulsed with less than the nominal coil voltage and pulse width should be a minimum of three
times the specified operate time of the relay. If these conditions are not followed, it is possible for the relay to
be in the magnetically neutral position .
2.Switching voltage is for test purpose only and are no to be used as design criteria.
151