English
Language : 

HR1A100KC Datasheet, PDF (1/2 Pages) DB Lectro Inc – ALUMINIUM ELECTROLYTIC CAPACITOR
RoHS Compliant ALUMINIUM ELECTROLYTIC CAPACITOR
FEATURES
◆ Load life of 5000 hours at 105°C
◆ Applications for switching power supplies
◆ Low impedance and low ESR with high ripple current
OUTLINE
HR Series
SPECIFICATIONS
Items
Capacitance Tolerance
(120Hz, 25°C)
Rated Working Voltage Range
Operation Temperature
Leakage Current (25°C)
Surge Voltage (25°C)
Dissipation Factor (120Hz, 25°C)
Temperature Characteristics
Load Test
Shelf Test
mm
D 8 10 13 16 18
F 3.5
5.0
7.5
d
0.6
0.8
Characteristics
± 20% (M)
10 ~ 100Vdc
-40°C ~ +105°C
(After 3 minutes applying the DC working voltage)
I ≤ 0.01CV
◆ I : Leakage Current (u A)
◆ C : Rated Capacitance (u F)
◆ V : Working Voltage (V)
W.V.
10
16
25
35
50
63
100
S.V.
13
20
32
44
63
79
125
W.V.
10
16
25
35
50
63
100
tan δ
0.12
0.10
0.09
0.08
0.07
0.06
0.06
◆ For capacitance exceeding 1000 u F, add 0.02 per increment of 1000 u F
W.V.
10 ~ 16
25 ~ 100
- 25°C / + 25°C
3
2
- 40°C / + 25°C
6
4
◆ Impedance ratio at 120Hz
After 2000 hours application of WV at +105°C, the capacitor shall meet the following limits:
(3000 hours for 10φ and 13φ, 5000 hours for 16φ and larger)
Capacitance Change ≤ ± 25% of initial value
tan δ
≤ 150% of initial specified value
Leakage Current
≤ initial specified value
After 1000 hours, no voltage applied at +105°C, the capacitor shall meet the following limits:
Capacitance Change ≤ ± 25% of initial value
tan δ
≤ 150% of initial specified value
Leakage Current
≤ 200% of initial specified value
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com