FEATURES
◆ Load life of 5000 hours at 105°C
◆ Safety vent construction design
◆ For electronic ballast circuits, switching power supply, automotive and other
long life required applications
OUTLINE
HL Series
SPECIFICATIONS
Items
Capacitance Tolerance
(120Hz, 25°C)
Rated Working Voltage Range
Operation Temperature
Leakage Current (25°C)
Surge Voltage (25°C)
Dissipation Factor (120Hz, 25°C)
Temperature Characteristics
Load Test
Shelf Test
mm
D 10 13 16 18
F
5.0
7.5
d
0.6
0.8
Characteristics
± 20% (M)
160 ~ 400Vdc
450Vdc
-40°C ~ +105°C
-40°C ~ +105°C
(After 2 minutes applying the DC working voltage)
I ≤ 0.06CV + 10 (u A)
◆ I : Leakage Current (u A)
◆ C : Rated Capacitance (u F)
◆ V : Working Voltage (V)
W.V.
160
200
250
350
400
450
S.V.
200
250
300
400
450
500
W.V.
160
200
250
350
400
450
tan δ
0.15
0.15
0.15
0.20
0.24
0.24
W.V.
160
200
250
350
400
450
- 25°C / + 25°C
3
3
3
5
5
6
- 40°C / + 25°C
6
6
6
6
6
-
◆ Impedance ratio at 120Hz
After 5000 hours application of WV at +105°C, the capacitor shall meet the following limits:
Capacitance Change ≤ ± 20% of initial value
tan δ
≤ 200% of initial specified value
Leakage Current
≤ initial specified value
After 1000 hours, no voltage applied at +105°C, the capacitor shall meet the following limits:
Capacitance Change ≤ ± 25% of initial value
tan δ
≤ 200% of initial specified value
Leakage Current
≤ 200% of initial specified value