English
Language : 

HG4506 Datasheet, PDF (1/2 Pages) DB Lectro Inc – Single Phase Motor Starter Relay
Single Phase Motor Starter Relay
HG4506
FEATURES
Specially designed for compressor use
Quick connects for quick hook-up
Class B insulation material
"Great Wall" mark approved
Other approvals pending
TYPICAL APPLICATIONS
Compressors in refrigerator, air conditioner, HVAC, etc.
Similar applications where starter relay is used
CONTACT RATING
Form
Make + Break
Break Only
1 Form B (D)
16A, 250VAC, cos
35A, 250VAC, cos
= 0.85
= 0.85
CONTACT DATA
Material
Initial Contact Resistance
Service Life
Mechanical
Electrical
AgCdO
50 mΩ max. at 0.1A, 6VDC
5 x 105 ops.
3 x 105 ops.
COIL DATA
Coil Voltage
Code
3G
6N
Resistance
(Ω) ±10%
7500
15000
Must Operate
Voltage Range
( VAC)
180 - 195
260 - 280
Must Release
Voltage Range
( VAC)
40 - 105
60 - 135
Power
Consumption
max.
5 VA
CHARACTERISTICS
Operate Time
Release Time
Insulation Resistance
Dielectric Strength
Shock Resistance
Vibration Resistance
Ambient Temperature
Weight
20 ms. max.
20 ms. max.
500 MΩ, at 500 VDC, 50%RH
1200 Vrms, 1 min. between open contacts
10 g, 11ms. functional
DA 1.5mm, 10 - 55 Hz
-25ºC to 85ºC
100 g, approx.
ORDERING DESIGNATION
Example:
HG4506 /
3G -
D
2
C
Model
Coil Voltage Code
3G: 180 - 195 VAC
6N: 260 - 280 VAC
Contact Form
D: 1 Form B
Version
1: Sealed; 2: Dust Cover
Contact Material
C: AgCdO; S: AgSnOInO
HG4506 1/2