English
Language : 

PDU138 Datasheet, PDF (3/5 Pages) Data Delay Devices, Inc. – 3-BIT PROGRAMMABLE DELAY LINE (SERIES PDU138)
DEVICE SPECIFICATIONS
PDU138
TABLE 1: AC CHARACTERISTICS
PARAMETER
Total Programmable Delay
Inherent Delay
Disable to Output Low Delay
Address to Enable Setup Time
Address to Input Setup Time
Enable to Input Setup Time
Output to Address Change
Disable Hold Time
Absolute
Input Period
Suggested
Recommended
Absolute
Input Pulse Width
Suggested
Recommended
SYMBOL
TDT
TD0
TDISO
TAENS
TAIS
TENIS
TOAX
TDISH
PERIN
PERIN
PERIN
PWIN
PWIN
PWIN
MIN
2.0
12.0
12.0
See Text
See Text
20
50
200
10
25
100
TYP
7
7.0
12.0
UNITS
TINC
ns
ns
ns
ns
ns
% of TDT
% of TDT
% of TDT
% of TDT
% of TDT
% of TDT
TABLE 2: ABSOLUTE MAXIMUM RATINGS
PARAMETER
SYMBOL MIN
MAX UNITS NOTES
DC Supply Voltage
Input Pin Voltage
Storage Temperature
Lead Temperature
VCC
VIN
TSTRG
TLEAD
-0.3
7.0
V
-0.3
VDD+0.3
V
-55
150
C
300
C
10 sec
TABLE 3: DC ELECTRICAL CHARACTERISTICS
(0C to 70C, 4.75V to 5.25V)
PARAMETER
SYMBOL MIN
High Level Output Voltage
VOH
2.5
Low Level Output Voltage
VOL
High Level Output Current
IOH
Low Level Output Current
IOL
High Level Input Voltage
VIH
2.0
Low Level Input Voltage
VIL
Input Clamp Voltage
VIK
Input Current at Maximum
IIHH
Input Voltage
High Level Input Current
IIH
Low Level Input Current
IIL
Short-circuit Output Current
IOS
-60
Output High Fan-out
Output Low Fan-out
TYP
3.4
0.35
MAX
0.5
-1.0
20.0
0.8
-1.2
0.1
20
-0.6
-150
25
12.5
UNITS
V
V
mA
mA
V
V
V
mA
NOTES
VCC = MIN, IOH = MAX
VIH = MIN, VIL = MAX
VCC = MIN, IOL = MAX
VIH = MIN, VIL = MAX
VCC = MIN, II = IIK
VCC = MAX, VI = 7.0V
µA
mA
mA
Unit
Load
VCC = MAX, VI = 2.7V
VCC = MAX, VI = 0.5V
VCC = MAX
Doc #02004
DATA DELAY DEVICES, INC.
3
5/6/02
3 Mt. Prospect Ave. Clifton, NJ 07013