English
Language : 

3010 Datasheet, PDF (3/3 Pages) Data Delay Devices, Inc. – VOLTAGE-VARIABLE DELAY LINE TR < 1ns
3010
PASSIVE DELAY LINE TEST SPECIFICATIONS
TEST CONDITIONS
INPUT:
Ambient Temperature:
Input Pulse:
Source Impedance:
Rise/Fall Time:
Pulse Width:
Period:
25oC ± 3oC
High = 1.8V typical
Low = 0.8V typical
50Ω Max.
3.0 ns Max. (measured
at 10% and 90% levels)
PWIN = 500ns
PERIN = 1000ns
OUTPUT:
Rload:
Cload:
Threshold:
50Ω
<10pf
50% (Rising & Falling)
NOTE: The above conditions are for test only and do not in any way restrict the operation of the device.
INPUT
SIGNAL
OUTPUT
SIGNAL
TRISE
PWIN
PERIN
TFALL
90%
VIH
90%
50%
10%
50%
10%
VIL
DRISE
TRISE
DFALL
90%
50%
10%
VOH
90%
50%
10%
Timing Diagram For Testing
TFALL
VOL
PULSE
GENERATOR
OUT (50Ω)
TRIG
IN DEVICE UNDER OUT
TEST (DUT)
+
VC
Test Setup
IN (50Ω)
TRIG
OSCILLOSCOPE
Doc #04001
DATA DELAY DEVICES, INC.
3
8/10/2005
3 Mt. Prospect Ave. Clifton, NJ 07013