English
Language : 

2075 Datasheet, PDF (2/2 Pages) List of Unclassifed Manufacturers – data delay devices
2075/2075A
PASSIVE DELAY LINE TEST SPECIFICATIONS
TEST CONDITIONS
INPUT:
Ambient Temperature:
Source Amplitude:
Source Impedance:
Input Frequency:
25oC ± 3oC
0dBm typical
75Ω nominal
27.777778MHz
OUTPUT:
Zload:
75Ω nominal
Network analyzer is used in phase measurement mode, normalized with a calibrated BNC jumper between
input and output signals. Delay is related to phase lag with proportionality constant of 100ps/deg.
NOTE: The above conditions are for test only and do not in any way restrict the operation of the device.
OUT
IN R
IN A
NETWORK
ANALYZER
(HP 3577A)
IN B
RF
50-Ohm Coax
50-Ohm Coax
50-OHM
IN
SIGNAL
DIVIDER
OUT R (HP 35676
-66301)
OUT A
OUT B
50-Ohm Coax
Test Setup
50-Ohm Coax
IMPEDANCE MATCHING
NETWORKS
50Ω
GND
50Ω
GND
75Ω
GND
75Ω
GND
IN
GND
DEVICE
UNDER
TEST
OUT
GND
Doc #01010
DATA DELAY DEVICES, INC.
2
11/2/01
Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com