English
Language : 

DDU12H Datasheet, PDF (1/4 Pages) Data Delay Devices, Inc. – 5-TAP, ECL-INTERFACED FIXED DELAY LINE (SERIES DDU12H)
5-TAP, ECL-INTERFACED
FIXED DELAY LINE
(SERIES DDU12H)
DDU12H
data
delay
3
®
devices, inc.
FEATURES
GND
• Ten equally spaced outputs
• Fits in 300 mil 32-pin DIP socket
T2
T4
• Input & outputs fully 10KH-ECL interfaced & buffered IN
VEE
GND
T2
T4
DDU12H-xx DIP
DDU12H-xxM Military DIP
VEE
PACKAGES
1 32 GND
31 T1
3 30 T3
4 29 T5
5
8
9 24
23
11 22
12 21
GND
T6
T8
T10
GND
T2
T4
IN
N/C
VEE
GND
N/C
N/C
T7
T8
VEE
1
24
2
23
3
22
4
21
5
20
6
19
7
18
8
17
9
16
10 15
11 14
12 13
GND
T1
T3
T5
N/C
N/C
GND
N/C
N/C
T6
T8
T10
DDU12H-xxC3 SMD
DDU12H-xxMC3 Mil SMD
16
FUNCTIONAL DESCRIPTION
PIN DESCRIPTIONS
The DDU12H-series device is a 10-tap digitally buffered delay line. The
IN Signal Input
signal input (IN) is reproduced at the outputs (T1-T10), shifted in time by
T1-T10 Tap Outputs
an amount determined by the device dash number (See Table). For dash VEE -5 Volts
numbers less than 20, the total delay of the line is measured from T1 to
GND Ground
T10. The nominal tap-to-tap delay increment is given by one-ninth of the
total delay, and the inherent delay from IN to T1 is nominally 1.5ns. For dash numbers greater than or
equal to 20, the total delay of the line is measured from IN to T10. The nominal tap-to-tap delay increment
is given by one-tenth of this number.
SERIES SPECIFICATIONS
DASH NUMBER SPECIFICATIONS
• Minimum input pulse width: 10% of total delay
• Output rise time: 2ns typical
• Supply voltage: -5VDC ± 5%
• Power dissipation: 400mw typical (no load)
• Operating temperature: -30° to 85° C
• Temp. coefficient of total delay: 100 PPM/°C
1.5ns 10% 10% 10% 10% 10% 10% 10% 10% 10%
VCC IN T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 GND
Functional diagram for dash numbers < 20
10% 10% 10% 10% 10% 10% 10% 10% 10% 10%
VCC IN T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 GND
Functional diagram for dash numbers >= 20
©1997 Data Delay Devices
Part
Number
DDU12H-10
DDU12H-20
DDU12H-25
DDU12H-40
DDU12H-50
DDU12H-75
DDU12H-100
DDU12H-150
DDU12H-200
DDU12H-250
DDU12H-300
DDU12H-400
DDU12H-500
DDU12H-750
DDU12H-1000
DDU12H-1500
Total
Delay (ns)
9 ± 1.0 *
20 ± 2.0
25 ± 2.0
40 ± 2.0
50 ± 2.5
75 ± 4.0
100 ± 5.0
150 ± 7.5
200 ± 10.0
250 ± 12.5
300 ± 15.0
400 ± 20.0
500 ± 25.0
750 ± 37.5
1000 ± 50.0
1500 ± 75.0
Delay Per
Tap (ns)
1.0 ± 0.3
2.0 ± 0.4
2.5 ± 0.4
4.0 ± 0.5
5.0 ± 1.0
7.5 ± 1.5
10.0 ± 2.0
15.0 ± 2.0
20.0 ± 2.0
25.0 ± 2.0
30.0 ± 2.0
40.0 ± 2.0
50.0 ± 2.5
75.0 ± 4.0
100.0 ± 5.0
150.0 ± 7.0
* Total delay is referenced to first tap output
Input to first tap = 1.5ns ± 1ns
NOTE: Any dash number between 10 and 1500
not shown is also available.
Doc #97036
DATA DELAY DEVICES, INC.
1
12/11/97
3 Mt. Prospect Ave. Clifton, NJ 07013