English
Language : 

2020 Datasheet, PDF (1/2 Pages) Data Delay Devices, Inc. – FIXED SIP DELAY LINE TR < 1ns
FIXED SIP DELAY LINE
TR < 1ns
(SERIES 2020 & 2021)
2020/2021
data
delay
3
®
devices, inc.
FEATURES
• Microstrip Technology
• Fast rise time for high frequency applications
• Delay available from 100ps to 2500ps
• Very narrow device (SIP package)
• Stackable for PC board economy
• Epoxy encapsulated
• Meets or exceeds MIL-D-23859C
123
PACKAGES
678
2020-xx
xx = Delay (TD)
G IN G
G OUT G
123
2021-xx
xx = Delay (TD)
IN G OUT
FUNCTIONAL DESCRIPTION
The 2020- and 2021-series devices are fixed, single-input, single-output,
passive delay lines. The signal input (IN) is reproduced at the output (OUT),
shifted by a time (TD) given by the device dash number. The characteristic
impedance of the lines is nominally 50 ohms. The rise time (TR) of the lines
is no more than 1ns, resulting in a 3dB bandwidth of at least 350MHz.
PIN DESCRIPTIONS
IN
OUT
G
Signal Input
Signal Output
Ground
SERIES SPECIFICATIONS
• Tolerance:
2% or 10ps
• Bandwidth:
>350MHz
• Ripple in pass-band:
Approx. 0.2dB
• Dielectric breakdown: >500 Vdc
• Operating temperature: -65°C to +125°C
• Temperature coefficient: <100 PPM/°C
IN
GND
Serpentine
Dielectric
Functional Diagram
OUT
GND
1.08 MAX.
.142
MAX.
Series
2020
.380
MAX.
G IN G
G OUT G
.200
MIN.
.020
.100 .100
.100 .100
DIA.
.500
.290
MAX.
Package Dimensions
.500
MAX.
Series
2021
IN G OUT
.100 .100 .150
MAX.
DASH NUMBER SPECIFICATIONS
Part
Number
2021-100
2021-150
2021-200
2021-250
2021-300
2021-350
2021-400
2021-500
2021-600
2021-700
Part
Number
2020-100
2020-150
2020-200
2020-250
2020-300
2020-350
2020-400
2020-500
2020-600
2020-700
2020-800
2020-900
2020-1000
2020-1100
2020-1200
2020-1300
2020-1400
2020-1500
2020-1600
2020-1750
Delay
(ps)
100 ± 10
150 ± 10
200 ± 10
250 ± 10
300 ± 10
350 ± 10
400 ± 10
500 ± 10
600 ± 12
700 ± 14
800 ± 16
900 ± 18
1000 ± 20
1100 ± 22
1200 ± 24
1300 ± 26
1400 ± 28
1500 ± 30
1600 ± 32
1750 ± 35
Imped.
(Ω)
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
©2001 Data Delay Devices
Doc #01009
DATA DELAY DEVICES, INC.
1
10/31/01
3 Mt. Prospect Ave. Clifton, NJ 07013