English
Language : 

DS1624 Datasheet, PDF (15/16 Pages) Dallas Semiconductor – Digital Thermometer and Memory
AC ELECTRICAL CHARACTERISTICS
PARAMETER
SYMBOL
Input Capacitance
CI
DS1624
(-55°C to +125°C; VDD=2.7V to 5.5V)
MIN TYP MAX UNITS NOTES
5
pF
NOTES:
1. All voltages are referenced to ground.
2. I/O pins of fast mode devices must not obstruct the SDA and SCL lines if V DD is switched off.
3. ICC specified with SDA pin open.
4. ICC specified with V CC at 5.0V and SDA, SCL = 5.0V, 0°C to 70°C.
5. After this period, the first clock pulse is generated.
6. The maximum tHD:DAT has only to be met if the device does not stretch the LOW period (tLOW) of the
SCL signal.
7. A fast mode device can be used in a standard mode system, but the requirement tSU:DAT >250 ns must
then be met. This will automatically be the case if the device does not stretch the LOW period of the
SCL signal. If such a device does stretch the LOW period of the SCL signal, it must output the next
data bit to the SDA line tRMAX+tSU:DAT = 1000+250 = 1250 ns before the SCL line is released.
8. Cb – total capacitance of one bus line in pF.
9. Writing to the nonvolatile memory should only take place in the 0°C to 70°C temperature range.
10. See Typical Curve for specification limits outside the 0°C to 70°C temperature range. Thermometer
error reflects sensor accuracy as tested during calibration.
TIMING DIAGRAMS
15 of 16