English
Language : 

DS1722 Datasheet, PDF (12/13 Pages) Dallas Semiconductor – Digital Thermometer with SPI/3-Wire Interface
TIMING DIAGRAM: SPI WRITE DATA TRANSFER Figure 12
DS1722
*SCLK can be either polarity, timing shown for CPOL = 1.
NOTES:
1. All voltages are referenced to ground.
2. Logic 0 voltages are specified at a sink current of 4 mA.
3. Logic 1 voltages are specified at a source current of 1 mA.
4. ICC specified with SCLK=VDDD and CE=GND. Typical ICC1 is 0.25 µA and ICC is 0.3 mA at 25°C
and VDDD = 2.65V.
5. Measured at VIH =0.7 VDDD or VIL=0.2 VDDD and 10 ms maximum rise and fall time.
6. Measured with 50 pF load
7. Measured at VOH =0.7 VDDD or VOL =0.2 VDDD. Measured from the 50% point of SCLK to the VOH
minimum of SDO.
8. Figure 13 shows mean thermometer error for a pre-characterization sample. Data covering a larger
sample over the full temperature range is pending.
12 of 13