English
Language : 

S3A Datasheet, PDF (1/2 Pages) Pan Jit International Inc. – SURFACE MOUNT RECTIFIER(VOLTAGE- 50-100 Volts CURRENT- 3.0 Ampere)
S3A THRU S3M
Features
· For surface mounted applications
· Glass passivated junction
· Low profile package
· Built-in strain relief, ideal for automated placement
· Plastic package has Unerwrites Laboratory
Flammability Classification 94V-0
· High temperature soldering guaranteed: 250 /10
seconds, at terminals
Mechanical Data
· Case : JEDEC SMC(DO-214AB) molded plastic body
· Terminals : Plated axial lead solderable per
MIL-STD-750, method 2026
· Polarity : Color band denotes cathode end
· Mounting Position : Any
· Weight : 0.007 ounce, 0.25 gram
CURRENT 3.0 Amperes
VOLTAGE 50 to 1000 Volts
DO-214AB (SMC)
0.124(3.15)
0.108(2.75)
0.245(6.22)
0.220(5.59)
0.280(7.11)
0.260(6.60)
0.103(2.62)
0.079(2.00)
0.012(0.31)
0.006(0.15)
0.050(1.27)
0.030(0.76)
0.008(0.203)
MAX.
0.320(8.13)
0.305(7.75)
Dimensions in inches and (millimeters)
Maximum Ratings And Electrical Characteristics
(Ratings at 25 ambient temperature unless otherwise specified, Single phase, half wave 60Hz, resistive or inductive
load. For capacitive load, derate by 20%)
Symbols S3A S3B S3D S3G S3J S3K
Maximum recurrent peak reverse voltage
Maximum RMS voltage
VRRM
VRMS
50
100 200
400
600
800
35
70
140
280
420
560
Maximum DC blocking voltage
VDC
50
100 200
400
600
800
Maximum average forward rectified current
at TL=75 (Note 2)
I(AV)
Peak forward surge current 8.3ms half sine
wave superimposed on rated load
IFSM
(JEDEC method) TL=75
Maximum instantaneous forward voltage
at 1.0A
VF
3.0
100.0
1.15
Maximum reverse
current at rated voltage
TA=25
TA=125
Typical thermal resistance (Note 2)
Typical reverse capacitance (Note 3)
Typical junction capacitance (Note 1)
Operating and storage temperature range
IR
R JL
R JA
trr
CJ
TJ
TSTG
1.0
250
13.0
47.0
2.5
60.0
-55 to +175
Notes:
(1) Measured at 1MHz and applied reverse voltage of 4.0V dc.
(2) Thermal resistance from junction to ambient and from junction to lead mounted on 0.2
copper opad areas.
(3) Reverse recovery test conditions:IF=0.5A, IR=1.0A, Irr=0.25A
0.2"(0.5
0.5mm)
S3M
1000
700
1000
Units
Volts
Volts
Volts
Amps
Amps
Volts
A
/W
S
pF