English
Language : 

CY8C21345_13 Datasheet, PDF (35/39 Pages) Cypress Semiconductor – PSoC® Programmable System-on-Chip
CY8C21345
CY8C22345
CY8C22545
Appendix: Silicon Errata for the PSoC® CY8C21x45, CY8C22x45 Product Family
This section describes the errata for the CY8C21x45, CY8C22x45 family of PSoC devices. Details include errata trigger conditions,
scope of impact, available workarounds, and silicon revision applicability.
Contact your local Cypress Sales Representative if you have questions.
Part Numbers Affected
Part Number
CY8C21345
CY8C21645
CY8C22045
CY8C22345
CY8C22545
CY8C22645
Device Characteristics
All Variants
All Variants
All Variants
All Variants
All Variants
All Variants
CY8C21x45, CY8C22x45 Qualification Status
Product Status: In Production
Errata Summary
The following table defines the errata applicable for this PSoC family device.
Items
Part Number
1. Free Running Nonstop Reading All CY8C21x45, CY8C22x45
cause 7 LSB Pseudo Code Variation devices affected
in SAR10ADC
2. Internal Main Oscillator (IMO)
All CY8C21x45, CY8C22x45
Tolerance Deviation at Temperature devices affected
Extremes
Silicon Revision
All
Fix Status
Silicon fix not planned. Use
workaround.
All
Silicon fix not planned. Use
workaround.
1. Free Running Nonstop Reading cause 7 LSB Pseudo Code Variation in SAR10ADC
■ Problem Definition
In free running mode, there can be a variation of up to 7 LSB in the digital output of SAR10 ADC.
■ Parameters Affected
Code Variation. This is not a specified parameter.
It is defined as the number of unique output codes generated by the ADC for a given constant input voltage, in addition to the correct
code. For example, for an input voltage of 2.000 V, the expected code is 190hex and the ADC generates three codes: 191hex, 190hex,
and 192hex. The code variation is 2 LSB.
■ Trigger Condition(S)
SAR10 ADC is configured in the free running mode.
■ Scope of Impact
Inaccurate output is possible.
■ Workaround
This issue can be averted by using one or both of the following workarounds. Consult a Cypress representative for additional
assistance.
❐ Use the averaging technique. That is, take multiple samples of the input, and use a digital averaging filter.
❐ Disable the free running mode before reading data out, and enable the free running mode after completing the read operation.
■ Fix Status
No silicon fix is planned.
Document Number: 001-43084 Rev. *Q