English
Language : 

CY7C9689 Datasheet, PDF (31/48 Pages) Cypress Semiconductor – TAXI Compatible HOTLink Transceiver
CY7C9689 HOTLink Receiver Switching Waveforms
Read Cycle
Asynchronous (FIFO) Interface
EXTFIFO=HIGH
FIFOBYP=HIGH
RXCLK
RXEN
tRXENS
READ
RXEMPTY
Note 36
LFI
RXFULL
RXHALF
RXDATA[7:0]
RXDATA[9:8/RXCMD[2:3]
RXCMD[1:0]
tRXCLKOP
tRXCLKIP
tRXCLKOD
tRXCLKOD
tRXCPWH
tRXCPWL
tRXENH
tRXA
NO OPERATION
tRXA
FIFO EMPTY
VALID DATA
Note 37
CE
CY7C9689
READ
Read Cycle
Asynchronous (FIFO) Interface
EXTFIFO=LOW
FIFOBYP=HIGH
RXCLK
RXEN
tRXENS
READ
RXEMPTY
LFI
RXFULL
RXHALF
RXDATA[7:0]
RXDATA[9:8/RXCMD[2:3]
RXCMD[1:0]
CE
tRXENH
tRXA
VALID DATA
tRXA
FIFO EMPTY
Note 38
Notes:
36. When transferring data from the Receive FIFO to a depth expanded external FIFO, the data is sent to the external FIFO on the same clock cycle that
RXEN=HIGH. RXEMPTY=LOW indicates that data is available.
37. On inhibited reads, or if the Receive FIFO goes empty, the data outputs do not change.
38. When reading data from synchronous data interface, the data is captured on any clock cycle that RXEN=LOW. RXEMPTY=HIGH indicates data is available.
RXEMPTY=LOW indicates that the FIFO is empty.
31