English
Language : 

CY7C1347D Datasheet, PDF (14/21 Pages) Cypress Semiconductor – 128K x 36 Synchronous-Pipelined Cache SRAM
CY7C1347D
Maximum Ratings
(Above which the useful life may be impaired. For user guide-
lines, not tested.)
Voltage on VCC Supply Relative to VSS ......... –0.5V to +4.6V
VIN ...........................................................–0.5V to VCC+0.5V
Storage Temperature (plastic) ...................... –55°C to +150°
Junction Temperature ..................................................+150°
Power Dissipation.......................................................... 1.0W
Short Circuit Output Current ........................................ 50 mA
Operating Range
Range
Com’l
Ambient
Temperature[15]
0°C to +70°C
VCC
3.3V −5%/+10%
Electrical Characteristics Over the Operating Range
Parameter
Description
Test Conditions
VIH
Input High (Logic 1)
Voltage: Inputs[10, 11]
VCCQ = 3.3 V
VCCQ = 2.5V
Input High (Logic 1)
Voltage: Data[10, 11]
VCCQ = 3.3 V
VCCQ = 2.5V
VIL
Input Low (Logic 0) Voltage: Inputs
and Data[10, 11]
VCCQ = 3.3 V
VCCQ = 2.5V
ILI
Input Leakage Current
0V < VIN < VCC
ILI
MODE and ZZ Input Leakage
Current[17]
0V < VIN < VCC
ILO
Output Leakage Current
VOH
Output High Voltage[10]
VOL
Output Low Voltage[10]
VCC
VCCQ
Supply Voltage[10]
I/O Supply Voltage[10]
Output(s) disabled, 0V < VOUT < VCC
VCC = Min, VCCQ = 3.3 V, IOH = –4.0 mA
VCC = Min, VCCQ = 2.5V, IOH = –2.0 mA
VCC = Min, VCCQ = 3.3V, IOL = 8.0 mA
VCC = Min, VCCQ = 2.5V, IOH = 2.0 mA
VCC = Min, VCCQ = 2.5V, IOH = 1.0 mA
3.3 V Range
2.5 V Range
Min.
2.0
1.7
2.0
1.7
–0.5
–0.3
–5
–30
–5
2.4
2.0
3.135
3.135
2.375
Max.
4.6
4.6
VCCQ + 0.3
VCCQ + 0.3
0.8
0.7
5
30
5
0.4
0.7
0.4
3.6
3.6
2.9
Unit
V
V
V
V
V
µA
µA
µA
V
V
V
V
V
V
V
V
Parameter
Description
Conditions
Typ. -4 -4.4 -5
-6
ICC
Power Supply Current:
Operating[18, 19, 20]
Device selected; all inputs < VILor > VIH;
cycle time > tKC min.; VCC = Max.;
150
450 400 360
300
outputs open
ISB2
CMOS Standby[19, 20] Device deselected; VCC = Max.;
5
10 10 10 10
all inputs < VSS + 0.2 or >VCC – 0.2;
all inputs static; CLK frequency = 0
ISB3
TTL Standby[19, 20] Device deselected; all inputs < VIL
10
20
20
20
20
or > VIH; all inputs static;
VCC = Max.; CLK frequency = 0
ISB4
Clock Running[19, 20] Device deselected; all inputs < VIL or > VIH; 40
140 125 110
90
VCC = Max.; CLK cycle time > tKC min.
Notes:
15. TA is the case temperature.
16. Overshoot: VIH ≤ +6.0V for t ≤ tKC /2.
Undershoot:VIL ≤ –2.0V for t ≤ tKC /2.
17. Output loading is specified with CL = 5 pF as in AC Test Loads.
18. ICC is given with no output current. ICC increases with greater output loading and faster cycle times.
19. “Device Deselected” means the device is in Power-Down mode as defined in the truth table. “Device Selected” means the device is active.
20. Typical values are measured at 3.3V, 25°C, and 20-ns cycle time.
Unit
mA
mA
mA
mA
Document #: 38-05022 Rev. *D
Page 14 of 21