English
Language : 

CY7B991.2JC Datasheet, PDF (1/19 Pages) Cypress Semiconductor – Programmable Skew Clock Buffer
CY7B991
CY7B992
Programmable Skew Clock Buffer
Features
■ All output pair skew <100 ps typical (250 maximum)
■ 3.75 to 80 MHz output operation
■ User selectable output functions
❐ Selectable skew to 18 ns
❐ Inverted and non-inverted
❐ Operation at 1⁄2 and 1⁄4 input frequency
❐ Operation at 2x and 4x input frequency (input as low as 3.75
MHz)
■ Zero input to output delay
■ 50% duty cycle outputs
■ Outputs drive 50Ω terminated lines
■ Low operating current
■ 32-pin PLCC/LCC package
■ Jitter < 200 ps peak-to-peak (< 25 ps RMS)
Logic Block Diagram
TEST
Functional Description
The CY7B991 and CY7B992 Programmable Skew Clock Buffers
(PSCB) offer user selectable control over system clock functions.
These multiple output clock drivers provide the system integrator
with functions necessary to optimize the timing of high perfor-
mance computer systems. Each of the eight individual drivers,
arranged in four pairs of user controllable outputs, can drive
terminated transmission lines with impedances as low as 50Ω.
They can deliver minimal and specified output skews and full
swing logic levels (CY7B991 TTL or CY7B992 CMOS).
Each output is hardwired to one of the nine delay or function
configurations. Delay increments of 0.7 to 1.5 ns are determined
by the operating frequency with outputs that skew up to ±6 time
units from their nominal “zero” skew position. The completely
integrated PLL allows cancellation of external load and trans-
mission line delay effects. When this “zero delay” capability of the
PSCB is combined with the selectable output skew functions,
you can create output-to-output delays of up to ±12 time units.
Divide-by-two and divide-by-four output functions are provided
for additional flexibility in designing complex clock systems.
When combined with the internal PLL, these divide functions
enable distribution of a low frequency clock that are multiplied by
two or four at the clock destination. This facility minimizes clock
distribution difficulty, allowing maximum system clock speed and
flexibility.
FB
REF
PHASE
FREQ FILTER
DET
VCO AND
TIME UNIT
GENERATOR
FS
4F0
4Q0
4F1
SELECT
4Q1
INPUTS
(THREE
LEVEL)
3F0
SKEW
3Q0
3F1
3Q1
SELECT
2Q0
2F0
2F1
MATRIX
2Q1
1F0
1Q0
1F1
1Q1
Cypress Semiconductor Corporation • 198 Champion Court
Document Number: 38-07138 Rev. *B
• San Jose, CA 95134-1709 • 408-943-2600
Revised June 22, 2007