English
Language : 

IWR-5 Datasheet, PDF (1/1 Pages) Cynergy3 Co – Five Channel Wireless Receiver
IWR-5
Five Channel Wireless Receiver
Pairs with the IWPT wireless pressure transducer
User-selectable 1-5V or 4-20mA receiver output
Clean contact output for process, low battery or loss of signal
alarm function
Simple software or DIL switch pairing with IWPT pressure
transducers
Up to 750m range, line-of-sight
12 to 32 Vdc powered
End-to-end accuracy of ±0.25% FS BFSL
LED indication of wireless link
DIN rail or wall mounting kits available
Single channel receiver available - see data sheet IWR-1
Description
The IWR-5 is a five channel receiver designed to pair with the IWPT series of wireless pressure transducers to form a cost effective replacement of
the traditional wired pressure transducer. This offers a low cost solution to inaccessible or expensive installation environment
The receiver has user selectable voltage or mA outputs corresponding to the calibrated pressure range of the remote Wireless Pressure
Transducers and 5A rated changeover contacts for alarm functionality.
User channel configuration is possible with the use of the program, IWR-Set, which ensures minimal user set-up time and thus ensures a simple
solution to multi-channel pressure measurement applications. With the standard 0dBI antenna, a line-of-sight range of up to 500m can be
achieved and, using the optional 3dBI antenna, up to 750m (LOS) is achievable.
Electrical Protection
Receiver Input
Outputs (5 off)
User selectable 1-5V or 4-20mA
*Receiver Frequency
2.4GHz
Alarm Output (1 off)
5 Amp rated changeover contacts
System Channel
Standard setting, however
Receiver Update Rate*
10 seconds as standard.
user adjustable in multiple
Alternative user setable rates :
instrument systems.
- 1,5, 10 and 30 seconds
Antenna
Enclosure mounted 0dBi
*Consult IWPT Installation manual and data sheet for set-up of alternative transmission rates.
*Compliant with EN 300 328, V1.8.1
Enclosure Specifications
System Performance (@ +20°C)
Dimensions
160 mm x 80 mm x 57 mm
Accuracy
<±0.25% FS BFSL
Material*
Light grey ABS (RAL7035)
Setting Errors (offsets)*
Zero and Full Scale <±0.5% FS
Protection Class
IP65
* End-to-end zero tare function available , see user manual.
Weight
Installation Position**
* Other materials on request
255g inc. 0dBI antenna (+12g with 3dBI)
Any
Instrument Power Source
DC Power
12 to 32Vdc
** Consult Installation Manual to ensure adequate signal path between transmitter and receiver
Temperature Ratings
Operating Temperature
-10°C to +50°C
Storage Temperature
-20°C to +80°C
Ordering Codes
Pressure Transducer:
Single Channel Receiver:
Five Channel Receiver:
Five Channel Configuration Software*
3dBi Antenna (enclosure mount)
See IWPT & IWPTL datasheets
IWR-1
IWR-5
IWR-Set
IANT-3
*Download user configuration software here:- RS hyperlink
Cynergy3 Components Ltd.
7 Cobham Road
Ferndown Industrial Estate
Wimborne, Dorset BH21 7PE
ISO9001C E R T I F I E D
www.cynergy3.com
Telephone +44 (0) 1202 897969
Email:sales@cynergy3.com
IWR-5 2016
© 2016 Cynergy3 Components, All Rights Reserved. Specifications are subject to change without prior notice. Cynergy3 Components and the Cynergy3 Components logo are trademarks of Cynergy3 Components Limited.