English
Language : 

FSV10AR Datasheet, PDF (1/2 Pages) Cynergy3 Co – Inline Flow Switch for G1pipe
FSV10AR
Inline Flow Switch for G1”pipe
The FSV10AR can be used to control a
pump or some other equipment or process
via a relay output. If used in a pumped
system, the device has to be fitted in the
pipe above the pump.
General purpose switch for loads of up to 4A inductive
0.6 l/min or 3.0 l/min turn on flow rate
Automatic shut down on flow stop
Adjustable time delay from 0 to 10 seconds for
pump stop
1”BSP inline pipe connections
Technical Specification
Flow Tube Material
Enclosure material
Enclosure rating
Start up flow rate
Q. min
l/min
Max flow rate
Q max
l/min
Max Pressure
P max
bar
Max Temperature
T max
°C
Pipe connections
BSP
Pump stop delay range
sec
FSV10AR06
0.6
Brass
Polyamide
IP54
80
8
85
1”
0 - 10
Electrical Specification
Supply Voltage
Vac
24 or 240
Switching Voltage Max
Vac
250
Switching Power Max
kW
1
Switching Current Max
A
10 for resistive load
4A for motor load
Standard Parts
FSV10AR06
FSV10AR30
On flow rate Max Power
0.6l/min
750
3.0 l/min
750
Max Pump current
4A
4A
The FSV10AR output relay is energised
90
once the flow rate through the device
exceeds 0.6 l/min, or 3 l/min depending on
version.
The turn off time delay is adjustable
82
between 0 and 10 seconds.
A flow of less than 0.6 l/min , or 3.0 l/min
depending on version, whether due to a
lack of supply (e.g. tank empty) or to a
decrease in demand(e.g. tap closing), will
release the output relay.
FSV10AR30
3.0
Cynergy3 Components Ltd.
7 Cobham Road
Ferndown Industrial Estate
Wimborne, Dorset BH21 7PE
Telephone +44 (0) 1202 897969
Email:sales@cynergy3.com
ISO9001 C E R T I F I E D
www.cynergy3.com