English
Language : 

FSH10AR Datasheet, PDF (1/2 Pages) Cynergy3 Co – Flow switch for G1, G2, G3 or G4” pipes
FSH10AR
Flow switch for G1”, G2”, G3” or G4” pipes
The FSH10AR can be used to control a
pump or some other equipment or process
via a relay output. If used in a pumped
system, the device has to be fitted in the
pipe after the pump.
It could be for controlling a circulating or
centrifugal electric pump that is providing
increased pressure or flow within water
systems with storage tanks.
General purpose switch for loads of up to 4A inductive
20 l/min turn on flow rate
Automatic shut down on flow stop
Adjustable time delay from 0 to 10 seconds for
pump stop
1”BSP pipe connections for mounting
Technical Specification
Screw mount Material
Enclosure material
Enclosure rating
Start up flow rate
Q. min
l/min
Max Pressure
P max
bar
Max Temperature
T max
°C
Pipe connections
BSP
Pump stop delay range
sec
Brass
Polyamide
IP54
20
10
100
1”
0 - 10
Electrical Specification
Supply Voltage
Vac
24 or 240
Switching Voltage Max Vac
250
Switching Power Max
kW
1
Switching Current Max
A
10 for resistive load
4A for motor load
Standard Parts
FSH10AR
On flow rate Max Power
20 l/min
750
Max Load current
4A
95
The FSH10 switches the output, once the
flow rate through the pipe exceeds 20
l/min. When used to activate a pump, it
can give an increased flow and pressure,
dependant on the pump capacity.
The turn off time delay is adjustable
between 0 and 10 seconds.
94
22
A flow of less than 20 l/min, whether due
to a lack of supply (e.g. tank empty) or to a
decrease in demand(e.g. tap closing), will
113
turn the output off again.
Cynergy3 Components Ltd.
7 Cobham Road
Ferndown Industrial Estate
Wimborne, Dorset BH21 7PE
Telephone +44 (0) 1202 897969
Email:sales@cynergy3.com
ISO9001 C E R T I F I E D
www.cynergy3.com
© 2012 Cynergy3 Components, All Rights Reserved. Specifications are subject to change without prior notice. Cynergy3 Components and the Cynergy3 Components logo are trademarks of Cynergy3 Components Limited.