English
Language : 

NQB-420NWA-AN Datasheet, PDF (9/30 Pages) CUI INC – FULLY REGULATED ADVANCED BUS CONVERTERS
CUI Inc │ SERIES: NQB-N │ DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS
date 02/20/2013 │ page 9 of 30
Electrical Specification
12.0 V, 39 A / 468 W
TP1, TP3 = -40 to +90ºC, VI = 40 to 60 V.
Typical values given at: TP1, TP3 = +25°C, VI = 53 V, max IO, unless otherwise specified under Conditions.
Additional Cout = 3.9 mF, Configuration File: 19010-CDA 102 0314/002
parameter
conditions/description
min
typ
max
input voltage range (VI)
turn-off input voltage (VIoff)
turn-on input voltage (VIon)
internal input capacitance (CI)
output power (PO)
efficiency (η)
power dissipation (Pd)
input idling power (Pli)
input standby power (PRC)
switching frequency (fs)
output voltage setting and ac-
curacy (VOi)
output voltage tolerance band
(VO)
line regulation (VO)
load regulation (VO)
load transient voltage deviation
(Vtr)
load transient recovery time
(ttr)
ramp-up time (tr) - (from
10−90% of VOi)
start-up time (ts) - (from VI
connection to 90% of VOi)
VI shut-down fall time (tf) -
(from VI off to 10% of VO)
RC start-up time (tRC)
RC shut-down fall time (tRC) -
(from RC off to 10% of VO)
output current (IO)
current limit threshold (Ilim)
short circuit current (Isc)
recommended capacitive load
(Cout)
output ripple & noise (VOac)
over voltage protection (OVP)
remote control (RC)
decreasing input voltage
increasing input voltage
50% of max IO
max IO
50% of max IO, VI = 48 V
max IO, VI = 48 V
max IO
IO = 0 A, VI = 53 V
VI = 53 V (turned off with RC)
0-100% of max IO
TP1 = +25°C, VI = 53 V, IO = 39 A
0-100% of max IO
max IO
VI = 53 V, 1-100% of max IO
VI = 53 V, load step 25-75-25% of max IO, di/dt =
1 A/μs
VI = 53 V, load step 25-75-25% of max IO, di/dt =
1 A/μs
10-100% of max IO, TP1 = 25ºC, VI = 53 V
10-100% of max IO, TP1 = 25ºC, VI = 53 V
max IO
IO = 0 A, CO = 0 mF
max IO
max IO
IO = 0 A, CO = 0 mF
VO = 10.8 V, TP1, TP3 < max TP1, TP3
TP1 = 25ºC, see Note 1
TP1 = 25ºC, see Note 2
See ripple & noise section, max IO , see Note 3
TP1, TP3 = 25°C, VI = 53 V, 10-100% of max IO
sink current (note 4), see operating information
trigger level, decreasing RC-voltage
trigger level, increasing RC-voltage
40
36
38
0
11.88
11.76
0
41
0.1
37
39
18
96.7
95.7
96.8
95.6
21.2
2.8
0.4
140
12.0
31
5
±0.4
150
8
24
3
7
12
4.5
7
44
14
3.9
50
15.6
2.6
2.9
60
38
40
468
30.5
12.12
12.24
60
25
39
47
6
110
0.7
Note
1: OCP in hic-up mode
2: Low ESR-value
3: Cout = 100 µF, external capacitance
4: Sink current drawn by external device connected to the RC pin. Minimum sink current required guaranteeing activated RC function.
cui.com
units
V
V
V
μF
W
%
%
%
%
W
W
W
kHz
V
V
mV
mV
V
µs
ms
ms
ms
s
ms
ms
s
A
A
A
mF
mVp-p
V
mA
V
V