APPLICATION NOTES
1. Output load requirement
To ensure this module can operate efficiently and reliably, the minimum output load may not be less than 10% of the full load during
operation. If the actual output power is low, connect a resistor at the output end in parallel to increase the load.
2. Overload Protection
Under normal operating conditions, the output circuit of this product has no protection against overload. The simplest method to add
this is to add a circuit breaker to the circuit.
3. Recommended circuit
If you want to further decrease the input/output ripple, you can increase the capacitance accordingly or choose capacitors with low
ESR(see Figure 3 & Table 3). However, the capacitance of the output filter capacitor must be appropriate. If the capacitance is too
high, a startup problem might arise. For every channel of the output, to ensure safe and reliable operation, the maximum capacitance
must be less than the maximum capacitive load (see Table 4).
Figure 3
Single Ou tpu t
Vin
Cin
GN D
DC DC
+Vo
Cout
0V
Dual O utput
Vin
Cin
GN D
DC DC
+Vo
Cout
0V
Cout
-Vo
Table 3
Vin
(Vdc)
Cin Single Vo Cout
(µF)
(Vdc)
(µF)
Dual Vo
(Vdc)
Cout
(µF)
5
4.7
3.3
10
±3.3
4.7
12
2.2
5
10
±5
4.7
15
2.2
12
2.2
±12
1
24
1
15
1
±15
0.47
--
--
24
1
±24
0.47
Note: It’s not recommended to connect any external capacitors in
applications with less than 0.5 watt output.
Table 4
Single Vout Max. Capacitive Load
(Vdc)
(μF)
3.3
220
5
220
12
220
15
220
24
220
Note:
1. For each output.
Dual Vout
(Vdc)
3.3
5
12
15
24
Max. Capacitive Load1
(μF)
100
100
100
100
100
Notes:
1. Operation under minimum load will not damage the converter; however, they may not meet all specifications listed.
2. Max. capacitive load tested at input voltage range and full load.
3. It is recommended to use either ceramic capacitors or electrolytic capacitors on the input and the output. Using tantalum capacitors may increase the risk of failure.
4. All specifications measured at: Ta=25°C, humidity<75%, nominal input voltage and rated output load, unless otherwise specified.
cui.com