CMI-1240 Datasheet, PDF (4/5 Pages) CUI INC – piezo audio indicator
Reliability Test
Item
Operating (Life Test)
Part No: CMI-1240
Description: piezo audio indicator
Date: 9/19/2006
Unit: mm
Page No: 4 of 5
Test Condition
1. Continuous life test:
The part will be subjected to 48 hours of
continuous operation at +55°C with 12 V dc
applied.
2. Intermittent life test:
A duty cycle of 1 minute on, 1 minute off, a
minimum of 5,000 times at room temp
(+25 ±2°C) with 12 V dc applied.
Evaluation Standard
The buzzer will be measured after
being placed at +25°C for 4
hours. The value of the
oscillation frequency/current
consumption should be ±10%
compared to the initial
measurements. The SPL should
be within ±10dB compared to
the initial measurements.
Test Conditions
Standard Test Condition
Judgement Test Condition
a) Tempurature: +5 ~ +35°C b) Humidity: 45 - 85% c) Pressure: 860-1060 mbar
a) Tempurature: +25 ±2°C
b) Humidity: 60 - 70% c) Pressure: 860-1060 mbar
Recommended Temperature Profile for Reflow Oven
SMT Reflow Temperature Profile (Pb_Free)
Peak Temp 260ĘC
255ĘC
20~40 sec
ĘC
150ĘC
217ĘC
200ĘC
60~180 sec
60~150sec
Time [sec]