PROTECTIONS
parameter
over voltage protection
over current protection
over temperature protection
conditions/description
V1: latch off
V2: latch off
V1: auto recovery
V2
auto recovery
min
typ
max
units
13.2
110
14.5
Vdc
120
%
101.2
128.8
A
3
A
55
°C
SAFETY & COMPLIANCE
parameter
conditions/description
min
typ
insulation safety rating / test
voltage
input to output, reinforced
input to chassis, basic
3,000
1,500
isolation voltage
output to chassis
V2 to chassis/ground
100
100
grounding
the output signals are referenced to the A2 and B2
return connection
safety approvals
EN60950-1:2006+A11+A1+A12, IEC60950-1:2005+Amd 1,
CAN/CSA-C22.2 No.60950-1-07+A1:2011, UL 60950-1:2007
R12.11(NRTL Route), EEC/93/68/LVD, 2006/95/EC LVD
conducted emissions
FCC 15 Sub Part B, EN55022, Class A: tested with resistive load
radiated emissions
FCC 15 Sub Part B, EN55022, Class A: tested with resistive load
harmonic compliance
EN/IEC 61000-3-2:2009, Class A Harmonic Limits
Compliance Level: 230 Vac line voltage; 100% output load
flicker
EN/IEC 61000-3-3:2009 limits as specified in the standard:
flicker and voltage fluctuations
electrostatic discharge
EN/IEC 61000-4-2, ±8 kV operational air discharge, ±8 kV
contact discharge: all parameters to remain within limits, test
set up to be defined
RF electro-magnetic
field. amplitude
modulated
EN/IEC 61000-4-3 80~1000 MHz, 10 V/m, 80% AM
Modulation (1 kHz): all parameters to remain within limits, test
set up to be defined
immunity to fast
transients
EN/IEC 61000-4-4 Power lines: ±2 kV: all parameters to remain
within limits, test set up to be defined
surges (mains)
EN/IEC 61000-4-5 ±1kV line to line, ±2 kV line to earth,
Criteria A: all parameters to remain within limits, test set up to
be defined
RF continuous
conducted
EN/IEC 61000-4-6 150 kHz~80 MHz 3Vrms 80% AM (1 kHz),
Criteria A: all parameters to remain within limits, test set up to
be defined
voltage dips/
interruptions
IEC 61000-4-11 30% reduction for 10 ms, 60% reduction for
100 ms: Reset is permitted must be selfrecovering. Additionally,
the PSU shall not latch up during any brownout condition.
MTBF
as per Telcordia SR-332, Issue 2, Sept 2006
component stress method at Ta=40°C, full load
500,000
RoHS
2011/65/EU
WEEE
2012/19/EU
max
units
Vrms
Vrms
Vrms
Vdc
hours
ENVIRONMENTAL
parameter
conditions/description
min
typ
max
units
operating temperature1
0
50
°C
storage temperature
non-condensing
-40
70
°C
operating humidity
non-condensing
10
90
%
storage humidity
5
90
%
Notes:
1. PSA-1100-12-B: At 100~240 Vac input, maximum of 1100 W at Ta=29°C. At 100~240 Vac input, maximum of 740 W at Ta=50°C. At 200~240 Vac input, maximum of
1100 W at Ta=48°C.
cui.com