English
Language : 

PBO-3 Datasheet, PDF (3/9 Pages) CUI INC – AC-DC POWER SUPPLY
For more information, please visit the product page.
CUI Inc │ SERIES: PBO-3 │ DESCRIPTION: AC-DC POWER SUPPLY
date 10/18/2016 │ page 3 of 9
SAFETY & COMPLIANCE (CONTINUED)
parameter
conditions/description
min
typ
max
units
PFM
IEC/EN61000-4-8 Class A, 10 A/m (external circuit required, see figure 2)
voltage dips & interruptions
IEC/EN61000-4-11 Class B, 0%-70% (external circuit required, see figure 2)
MTBF
as per MIL-HDBK-217F at 25 °C
300,000
hours
RoHS
2011/65/EU
Notes:
1. The power supply is considered a component which will be installed into final equipment.The final equipment still must be tested to meet the necessary EMC directives.
ENVIRONMENTAL
parameter
operating temperature
storage temperature
storage humidity
conditions/description
see derating curves
non-condensing
min
typ
max
units
-40
85
°C
-40
105
°C
85
%
SOLDERABILITY
parameter
hand soldering
wave soldering
conditions/description
for 3~5 seconds
for 5~10 seconds
min
typ
max
units
350
360
370
°C
255
260
265
°C
250
200
150
100
50
0
DERATING CURVES
load vs. ambient temperature
(at 110~240 Vac / 100~340 Vdc input voltage)
Peak Temp. 260°C Max.
Wave Soldering Time
4 Sec. Max.
10 Sec. Max.
Time (sec.)
load vs. input voltage
(at 25°C)
100
80
Safe operating area
60
40
-40 -20
55
85
Ambient Temperature (°C)
100
80
Safe operating area
60
40
85
110
70
100
240 264
340 400
Input Voltage (Vac/Vdc)
cui.com