INPUT
parameter
input voltage
conditions/description
VQA-S9-D15-SIP
VQA-S12-D15-SIP
all other models
VQA-S24-D15-SIP
min
typ
9
12
11.6
12
14.5
15
23.3
24
OUTPUT
parameter
line regulation
conditions/description
for Vin change of 1%
VQA-S12-D15-SIP
VQA-S15-D15-SIP
VQA-S15-D17-SIP
VQA-S24-D15-SIP
for Vin change of 25%
VQA-S9-D15-SIP
min
typ
1.2
1.3
1.2
1.2
1.2
PROTECTIONS
parameter
short circuit protection
conditions/description
yes
min
typ
SAFETY AND COMPLIANCE
parameter
conditions/description
isolation voltage
tested for 1 minute at 1 mA max.
isolation capacitance
input to output, 1 kHz / 1 V
all other models
VQA-S15-D17-SIP
VQA-S9-D15-SIP
RoHS compliant
yes
min
typ
3,000
6.6
8
10
ENVIRONMENTAL
parameter
operating temperature
storage temperature
TEST CIRCUIT
conditions/description
VQA-S9-D15-SIP
all other models
min
typ
-40
-40
-50
1
7
A
Load
C2 + V
VIN
C1 +
DC-DC
converter 6
2
5
1
7
VIN
C1 +
DC-DC
converter
6
C3 + V
A
Load
2
5
max
15
12.4
15.5
24.7
max
1.5
1.5
1.5
1.5
1.5
max
max
10
max
105
85
125
units
Vdc
Vdc
Vdc
Vdc
units
%
%
%
%
%
units
units
Vac
pF
pF
pF
units
°C
°C
°C
APPLICATION CIRCUIT
Control Signal
Rg
IGBT Driver
1
7
C2 +
VIN
C1 +
DC-DC
converter
6
C3 +
2
5
C1*, C2, C3: 100 F/35V (low impedance)
* C1: 100 F/65V for S24 version
IGBT
VIN: S9, S12, S15
C1: 100 F/35V (low impedance)
C2: 100 F/35V (low impedance)
C3: 100 F/35V (low impedance)
VIN: S24
C1: 100 F/65V (low impedance)
C2: 100 F/35V (low impedance)
C3: 100 F/35V (low impedance)
cui.com
1. The wire between the converter and IGBT driver must as
short as possible.
2. External filter capacitors should be connected as close as
possible to the converter and the IGBT driver.
3. To ensure the high peak gate current, the filter capacitors
should be low impedance.
4. The output average power of the IGBT driver should be less
than the output power of DC-DC module.
5. In order to avoid over temperature damage for long time
short-circuit, the recommended short-circuit time is less
than ten minutes at 25°C.