English
Language : 

VMS-100-5_13 Datasheet, PDF (2/4 Pages) CUI INC – AC-DC POWER SUPPLY
CUI Inc │ SERIES: VMS-100 │ DESCRIPTION: AC-DC POWER SUPPLY
date 07/22/2013 page 2 of 4
INPUT
parameter
voltage
frequency
inrush current
conditions/description
at 240 Vac
min
typ
max
units
90
264
Vac
47
63
Hz
80
A
OUTPUT
parameter
line regulation
load regulation
temperature coefficient
hold-up time
adjustability
switching frequency
conditions/description
low line to high line, full load
10% to 100% full load
min
80
typ
±0.5
±1
±0.05
16
max
±5
100
units
%
%
%/°C
ms
%
kHz
PROTECTIONS
parameter
over voltage protection
short circuit protection
conditions/description
recycle ac input to restart
hiccup mode, recovers automatically
min
typ
max
units
SAFETY & COMPLIANCE
parameter
conditions/description
min
typ
max
units
isolation voltage
input to output
5,656
Vdc
safety approvals
IEC 60601-1, EN 60601-1, UL 60601-1
EMI/EMC
EN 55024, EN 61000-6-1, EN 61204-3, EN 60601-1-2, EN 61000-3-2 Class (A, B, C, D), EN 61000-3-3,
EN 55011 Class B, EN 55022 Class B, FCC Part 15 Class B
leakage current
0.3
mA
RoHS compliant
yes
MTBF
MIL-HDBK-217F, GB, at 25°C, 115 Vac
200,000
hrs
ENVIRONMENTAL
parameter
operating temperature
storage temperature
operating humidity
conditions/description
see derating curve
non-condensing
min
typ
max
units
-20
70
°C
-20
85
°C
93
%
MECHANICAL
parameter
dimensions
weight
cooling method
conditions/description
min
typ
max
units
127.00 x 76.20 x 26.67 (5.00 x 3.00 x 1.05 inch)
mm
270
g
free air convection (see derating curves below)
cui.com