English
Language : 

VEQ15 Datasheet, PDF (2/3 Pages) CUI INC – DC/DC converter
PART NUMBER: VEQ15 series
INPUT
input voltage range
input filter
OUTPUT
voltage accuracy single output
dual
+output
-output
triple 5V
12V/15V
voltage balance (dual)
transient response: single, 25% step load change
dualFL-1/2L ± 1% error band
External Trim Adj. Range
Ripple & Noise
20MHz BW
temperature coefficient
short circuit protection
line regulation1
single/dual
triple
load regulation2
single/dual
triple
GENERAL SPECIFICATIONS
efficiency
isolation voltage
Isolation resistance
switching frequency
operating temperature range
case temperature
cooling
storage temperature range
EMI/RFI
dimensions
case material
NOTES:
1. measured from high line to low line
2. measured from full load to 1/4 load
3. max. total power from all outputs is limted to 30 watts
but no output should be allowed to exceed its max. current
4. min. current on each output is required to maintain
specified regulation
DESCRIPTION: DC/DC converter
rev.
page 2 of 3
date 08/2007
24V: 9-36V
48V: 18-72V
PI type
±1.0% max.
±1.0% max.
±3.0% max.
±3.0% max.
±1.0% max.
±1.0% max.
<500µ sec.
<500µ sec.
±10%
10mV RMS., max
75mV p-p., max
±0.02%/°C
continuous
±0.2% max
±1.0% max
±1.0% max
±5.0% max
see table
500VDC min.
109 Ohms
200KHz, typical
-25°C to +71°C
100°C max
free air convection
-55°C to +105°C
six-sided continuous shield
2.56x3.0x0.83 inches
(65x76.2x21.1mm)
black coated copper with non-conductive base
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382