English
Language : 

VBM-100-12 Datasheet, PDF (2/4 Pages) CUI INC – AC-DC POWER SUPPLY
CUI Inc │ SERIES: VBM-100 │ DESCRIPTION: AC-DC POWER SUPPLY
date 07/17/2013 │ page 2 of 4
INPUT
parameter
voltage
frequency
inrush current
leakage current
no load power consumption
conditions/description
at 240 Vac
at 264 Vac
min
typ
max
units
90
264
Vac
47
63
Hz
100
A
3.5
mA
0.5
W
OUTPUT
parameter
line regulation
load regulation
voltage accuracy
hold-up time
switching frequency
temperature coefficient
conditions/description
high line to low line, full load
60% ±40% rated load
set at 60% rated load and 25°C
min
typ
16
130
±0.05
max
±0.5
±1
±1
units
%
%
%
ms
kHz
%/°C
PROTECTIONS
parameter
over voltage protection
short circuit protection
over temperature protection
conditions/description
recycle ac input to restart
hiccup mode, recovers automatically
auto recovery
min
typ
max
units
SAFETY AND COMPLIANCE
parameter
conditions/description
min
typ
max
units
isolation voltage
input to output
4,242
Vdc
safety approvals
IEC 60950-1, EN 60950-1, UL 60950-1
EMI/EMC
EN 55022 Class B, FCC Part 15 Class B, EN 61000-6-(1,3), EN 61000-3-(2,3), EN 55024, EN 61204-3
RoHS compliant
yes
ENVIRONMENTAL
parameter
operating temperature
storage temperature
humidity
conditions/description
see derating curves
non-condensing
min
typ
max
units
-20
85
°C
-40
100
°C
93
%
DERATING CURVES
100
80
115 Vac
230 Vac
115 Vac w/
heat sink
230 Vac w/
heat sink
60
40
20
0
-20
-10
0
10
20
30
40
50
60
70
80 85 90
Ambient Temperature (°C)
cui.com