VBED10 Series DC-DC Converter
Rev. 06-2006
Input
Input Voltage Range
Input Filter
Output
Voltage Accuracy Single Output
Dual +Output
-Output
Voltage Balence (Dual)
Transient Response: Single, 25% Step Load Change
Dual, FL-1/2±1% Error Band
Ripple & Noise
20MHz BW
Temperature Coefficient
Short Circuit Protection
Line Regulation1
Single/Dual output
Load Regulation2 Single/Dual output
General Specifications
Efficiency
Isolation Voltage
Isolation Resistance
Switching Frequency
Operating Temperature Range
Case Temperature
Storage Temperature
Cooling
EMI/RFI
Dimensions
Case Material
NOTES:
1. Measured from high line to low line
2. Measured from full load to 1/4 load
3. A minimum load on the output is necessarry to maintain regulation
12V: 9-18V
24V: 18-36V
48V: 36-72V
Pi Type
±1.0% max.
±1.0% max.
±1.0% max.
±1.0%max
<500µ sec.
<500µ sec.
100 mV p-p max
±0.02%/°C
continuous
±0.2% max.
±1.0% max.
see table
500VDC min.
109Ohm min.
200KHz, min.
-25°C to +71°C
100°C max.
-40°C to +100°C
Free air convection
Six Sided Continuous Shield
2x1x0.4 inches
(50.8x25.4x10.2mm)
Black coated copper with non-
conductive base
V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005
www.v-infinity.com