INPUT
parameter
operating input voltage
start-up voltage
surge voltage
filter
conditions/description
5 V input models
12 V input models
24 V input models
48 V input models
5 V input models
12 V input models
24 V input models
48 V input models
for maximum of 1 second
5 V input models
12 V input models
24 V input models
48 V input models
capacitance filter
min
typ
max
units
4.5
5
9
12
18
24
36
48
9
Vdc
18
Vdc
36
Vdc
75
Vdc
3.5
4
4.5
Vdc
4.5
8
9
Vdc
11
16
18
Vdc
24
33
36
Vdc
-0.7
-0.7
-0.7
-0.7
12
Vdc
25
Vdc
50
Vdc
100
Vdc
OUTPUT
parameter
conditions/description
line regulation
full load, input voltage from low to high
load regulation
5% to 100% load
voltage accuracy
5% to 100% load
no-load output voltage accuracy
5V output models
all other models
switching frequency
100% load, nominal input voltage
transient recovery time
25% load step change
transient response deviation
25% load step change
temperature coefficient
100% load
min
typ
±0.2
±0.4
±1
±1.5
±1.5
180
0.5
±3
±0.02
max
±0.5
±0.75
±3
±5
±3
1
±5
±0.03
units
%
%
%
%
%
KHz
ms
%
%/°C
PROTECTIONS
parameter
short circuit protection
over current protection
conditions/description
continuous, automatic recovery
min
typ
max
units
120
%
SAFETY AND COMPLIANCE
parameter
conditions/description
min
typ
max
units
isolation voltage
for 1 minute at 1 mA max.
3,000
Vdc
isolation resistance
at 500 Vdc
1,000
MΩ
conducted emissions
CISPR22/EN55022, class B, (external circuit required, see Figure 1-b)
radiated emissions
CISPR22/EN55022, class B, (external circuit required, see Figure 1-b)
ESD1
IEC/EN61000-4-2, class B, contact ± 4kV/ air ± 8kV
radiated immunity
IEC/EN61000-4-3, class A, 10V/m
EFT/burst
IEC/EN61000-4-4, class B, ± 2kV (external circuit required, see Figure 1-a)
surge
IEC/EN61000-4-5, class B, ± 2kV (external circuit required, see Figure 1-a)
conducted immunity
IEC/EN61000-4-6, class A, 3 Vr.m.s
voltage dips and interruptions IEC/EN61000-4-29, class B, 0%-70%
MTBF
as per MIL-HDBK-217F @ 25°C
1,000,000
hours
RoHS compliant
yes
Note:
1. 24V input models can only meet ESD contact ±2kV with external circuit 1-c hooked up. 24V input models can meet ESD contact ±4kV with external circuit 1-a, 1-b, and 1-c hooked up.
cui.com