INPUT
parameter
conditions/description
min
typ
max
units
voltage
frequency
current
inrush current1
15V, 18V and 24V model
at 100 Vac
at 132 Vac
all other models
at 132 Vac
D no load power consumption
level IV models
level V models
Notes:
1. inrush lasts no longer than 0.5 ms before settling to steady state current
100
47
132
Vac
63
Hz
0.15
A
15
A
30
A
40
A
0.5
W
0.3
W
OUTPUT E parameter
line regulation
U load regulation
temperature coefficient
start-up
PROTECTIONS N hold-up
conditions/description
all other models
7.5V model
0 ~ 40°C, full load, after initial 1 hour warm-up
time needed to reach regulation
at 115 Vac, full load
min
10
typ
±1
±2
±5
±0.02
max
3
units
%
%
%
%/°C
s
ms
I parameter
over voltage protection
short circuit protection
conditions/description
min
typ
max
units
clamped by internal protection zener
continuous, auto-recovery upon removal of short
SAFETY & COMPLIANCE T parameter
N isolation voltage
isolation resistance
safety approvals
safety
O EMI/EMC
leakage current
RoHS compliant
conditions/description
input to output at 10 mA for 1 minute
input to output at 500 Vdc
UL 1310
class II
FCC Part 15 Class B
yes
min
100
typ
max
units
3,000
Vdc
4,242
Vdc
MΩ
0.25
mA
ENVIRONMENTAL C parameter
operating temperature
S storage temperature
operating humidity
DI storage humidity
conditions/description
min
typ
max
units
0
40
°C
-10
70
°C
20
80
%
10
90
%
cui.com