English
Language : 

EPS-6W Datasheet, PDF (2/5 Pages) CUI INC – AC-DC POWER SUPPLY
CUI Inc │ SERIES: EPS 6W │ DESCRIPTION: AC-DC POWER SUPPLY
date 04/18/2013 │ page 2 of 5
INPUT
parameter
conditions/description
voltage
frequency
current
inrush current1
15V, 18V and 24V model
at 100 Vac
at 132 Vac
all other models
at 132 Vac
no load power consumption
level IV models
level V models
Notes:
1. inrush lasts no longer than 0.5 ms before settling to steady state current
OUTPUT
parameter
line regulation
load regulation
temperature coefficient
start-up
hold-up
conditions/description
all other models
7.5V model
0 ~ 40°C, full load, after initial 1 hour warm-up
time needed to reach regulation
at 115 Vac, full load
PROTECTIONS
parameter
over voltage protection
short circuit protection
conditions/description
clamped by internal protection zener
continuous, auto-recovery upon removal of short
SAFETY & COMPLIANCE
parameter
conditions/description
isolation voltage
input to output at 10 mA for 1 minute
isolation resistance
safety approvals
safety
EMI/EMC
leakage current
RoHS compliant
input to output at 500 Vdc
UL 1310
class II
FCC Part 15 Class B
yes
ENVIRONMENTAL
parameter
operating temperature
storage temperature
operating humidity
storage humidity
conditions/description
min
100
47
min
10
min
min
100
min
0
-10
20
10
typ
max
units
132
Vac
63
Hz
0.15
A
15
A
30
A
40
A
0.5
W
0.3
W
typ
±1
±2
±5
±0.02
max
3
units
%
%
%
%/°C
s
ms
typ
max
units
typ
max
units
3,000
Vdc
4,242
Vdc
MΩ
0.25
mA
typ
max
units
40
°C
70
°C
80
%
90
%
cui.com