INPUT
parameter
operating input voltage
current
power
starting voltage
conditions/description
12 Vdc input models
24 Vdc input models
48 Vdc input models
CFM-A225-13
CFM-A225-23
CFM-A225-43
CFM-A238-13
CFM-A238-23
CFM-A238-43
CFM-A225-13
CFM-A225-23
CFM-A225-43
CFM-A238-13
CFM-A238-23
CFM-A238-43
at 25°C
12 Vdc input models
24 Vdc input models
48 Vdc input models
PERFORMANCE
parameter
rated speed
air flow
static pressure
noise
conditions/description
at 25°C, after 10 minutes
CFM-A225 models
CFM-A238 models
at 0 mm H2O, see performance curves
CFM-A225 models
CFM-A238 models
at 0 CFM, see performance curves
CFM-A225 models
CFM-A238 models
at 1 m
CFM-A225 models
CFM-A238 models
PROTECTIONS / SIGNALS1
parameter
conditions/description
auto restart protection
available on all models
rotation detector
available on “11” models
tachometer signal
available on “20” and “22” models
PWM control signal
available on “22” models
Notes:
1. See application notes for details.
SAFETY & COMPLIANCE
parameter
conditions/description
insulation resistance of frame at 500 Vdc between frame and positive terminal
dielectric strength
at 500 Vac, 60 Hz, 1 minute between frame and
positive terminal
safety approvals
UL/cUL 507, TUV (EN 60950-1)
EMI/EMC
EN 55022:2010+AC:2011 Class B, EN 61000-3-
2:2014, EN 61000-3-3:2013, EN 55024:2010
life expectancy
at 45°C, 15~65% RH
RoHS
2011/65/EU
min
6
16
30
typ
12
24
48
0.59
0.31
0.17
1.40
0.77
0.36
7.08
7.44
8.16
16.80
18.48
17.28
6
12
24
max
13.8
27.6
55.2
0.79
0.39
0.23
1.75
0.88
0.48
9.48
9.36
11.04
21
21.12
23.04
units
Vdc
Vdc
Vdc
A
A
A
A
A
A
W
W
W
W
W
W
Vdc
Vdc
Vdc
min
3,690
4,140
typ
4,100
4,600
126.89
200.9
12.52
19.80
51.5
59.5
max
4,510
5,060
53.5
61.5
units
RPM
RPM
CFM
CFM
mm H2O
mm H2O
dBA
dBA
min
typ
max
units
min
typ
max
units
10
MΩ
5
mA
70,000
hours
cui.com