VQP-100-3D Switching Power Supply
Features
·Universal AC input / Full range
·Built-in active PFC function, PF>0.95
·Protections:Short circuit/Over load/Over voltage
·Free air cooling convection
·CH4: Polarity is selectable
·Fixed switching frequency at 100KHz(Optional)
·3 year warranty
DC output voltage
Output V. tolerance
Output rated current
Output current range
Ripple & noise p-p
Line regulation
Load regulation
Max. output power
Efficiency
DC voltage adj.
Input voltage range
AC current
Inrush current
Leakage current
Overload protection
Over voltage protection
Over temp. protection
Temperature coefficient
Set up, rise, hold up time
Power factor
Vibration
Withstand voltage
Isolation resistance
Working temp., humidity
Storage temp., humidity
Dimensions
Weight
Safety standards
EMC standards
CH1
CH2
CH3
CH4
5V
3.3V
24V
-12V
±3%
±3%
±6%
±5%
8A
8A
1.3A0
0.6A
2-10A
0-10A
0.3-2A
0-1A
100mV
100mV
±1%
±1%
±2%
±2%
100.6W
75%
CH1,2: +10, -5%
90~264VAC 47~63Hz; 120-370VDC
1.5A/115V 0.75A/230V
150mV
±2%
±6%
150mV
±1%
±2%
cold start<= 40A/230V
<3.5mA/240VAC
105%~150%, pulsing (hiccup mode), auto restart.
CH1:5.75~6.75V CH2:3.8~4.4V type: shutdown reset: re-power on
95°C±5°C TSW1 type: shutdown
reset: auto recovery
±0.3%/ °C(0~50°C)
800ms, 50ms, 16ms / 115, 230VAC
PF>0.95/230VAC, PF>0.98/115VAC
10~500Hz, 2G 10 min./1 cycle, period fo 60 min. each axes
I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC for 1 min.
I/P-O/P, I/P-FG, O/P-FG: 500VDC / 100M Ohms min.
-10°C~+60°C (refer to output derating curve), 20%-90% RH
-20°C~+85°C, 10%-95% RH
7.83x3.9x1.97 inches (199x99x50mm) case: 916A
1.61lbs (730gs)
UL1950, TUV EN60950 approved
EN55022 class B, EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-3-2,-3,
EN55024 verification
Notes:
1. All parameters are specified at 230VAC input, rated load, 25°C 70% RH ambient
2. Tolerance includes set up tolerance, line regulation, load regulation
3. Ripple & noise are measured at 20MHz by using a 12” twisted pair terminated with a 0.1uF & 47 uF capacitor
4. Line regulation is measured from low line to high line at rated load
5. Load regulation is measured from 20% to 100% rated load, and other outputs at 60% rated load.
6. Each output provides up to maximum current, but total load can not exceed max. output power.
V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise
customers to verify the most up-to-date product information before placing orders. V-Infinity assumes no liability or responsibility for
customer’s applications using V-Infinity products other than repair or replacing (at V-I’s option) V-Infinity products not meeting V-I’s
published specifications. Nothing will be covered outside of standard product warranty.
V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005