English
Language : 

VPPQ-100C Datasheet, PDF (1/2 Pages) CUI INC – 100W 3, 4 Output with PFC
•
VPPQ-100C 100W 3, 4 Output with PFC
Features
·Universal AC input / Full range
·Built-in active PFC function, PF>0.95
·Protections:Short circuit/Over load/Over voltage
·Cooling by free air convection
·100% full load burn-in test
·Fixed switching frequency at 70KHz(Optional)
·3 year warranty
DC output voltage
Output V. tolerance
Output rated current
Output current range
Ripple & noise
Line regulation
Load regulation
DC output power
Efficiency
DC voltage adj.
Input voltage range
AC current
Inrush current
Leakage current
Overload protection
Over voltage protection
Over temp. protection
Temperature coefficient
Set up, rise, hold up time
Power factor
Vibration
Withstand voltage
Isolation resistance
Working temp., humidity
Storage temp., humidity
Dimensions
Weight
Safety standards
EMC standards
CH1
CH2
CH3
CH4
5V
12V
-15V
-5V
±3%
+10, -6%
±5%
±5%
10A
2.6A
0.6A
0.6A
2-15A
0.3-4A
0-1A
0-1A
100mV
150mV
100mV
100mV
±1%
±2%
±2%
±1%
±2%
±6%
±2%
±2%
101W
76%
CH1:+10,-5%
90~264VAC 47~63Hz; 127~370VDC
1.65A/115V 0.85A/230V
cold start 40A
<3.5mA/240VAC
105%-135%
type: Hiccup mode, recovers automatically after fault condition is removed
CH1:5.75~6.75V
-------
±0.03% / ºC (0~50ºC) ON +5V output
1.2s,50ms,16ms @115VAC / 800ms, 50ms, 16ms @230VAC
PF>0.95/230VAC, PF>0.98/115VAC
10~500Hz, 2G 10 min./1 cycle, period of 60 min. each axes
I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC, for 1 min.
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms min.
-10°C~+60% (refer to output derating curve), 20%-90% RH
-20°C~+85°C, 10%-95% RH
7x4.25x1.5 inches (178x108x38 mm)
1.37 lb. (0.62 Kg)
UL1950, TUV EN60950
EN55022 CLASS B, EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-3-2,-3
Notes:
1. All parameters are specified at 230VAC input, rated load, 25°C 70% RH ambient
2. Tolerance includes set up tolerance, line regulation, load regulation
3. Ripple & noise are measured at 20MHz by using a 12” twisted pair terminated with a 0.1uF & 47 uF capacitor
4. Line regulation is measured from low line to high line at rated load
5. Load regulation is measured from 20% to 100% rated load, and oother output at 60% rated load
6. Each output provide up to maximum current, but total load cannot exceed max. output power
*V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise cus-
tomers to verify the most up-to-date product information before placing orders. V-Infinity assumes no liability or responsibility for cus-
tomer’s applications using V-Infinity products other than repair or replacing (at V-I’s option) V-Infinity products not meeting V-I’s pub-
lished specifications. Nothing will be covered outside of standard product warranty.
V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005
www.v-infinity.com 1-866-372-1258