English
Language : 

VPLN-60 Datasheet, PDF (1/2 Pages) CUI INC – switching power supply
page 1 of 2
date 12/10/2007
PART NUMBER: VPLN-60 Series
DESCRIPTION: switching power supply
features
·universal AC input / full range
·fully isolated plastic case with IP64 level
·built-in constant current limiting circuit with adjustable OCP level
·protections: short circuit/over load/over voltage/over temperature
·built-in active PFC function
·IP64 design for indoor or outdoor installations
·UL1310, Class 2 power unit
·100% full load burn-in test
·cooling by free air convection
·suitable for LED lighting and moving sign applications
·high realibility
·2 year warranty
Model
VPLN-60-12 VPLN-60-15 VPLN60-20 VPLN-60-24 VPLN-60-27 VPLN-60-36 VPLN-60-48
DC output voltage
12V
15V
20V
24V
27V
36V
48V
Vout tolerance3
±10%
±10%
±10%
±10%
±10%
±10%
±10%
output rated current
5A
4A
3A
2.5A
2.3A
1.7A
1.3A
output min. range
0A
0A
0A
0A
0A
0A
0A
output max. range
5A
4A
3A
2.5A
2.3A
1.7A
1.3A
peak load
ripple & noise2
60W
2Vp-p
60W
2.4Vp-p
60W
1.8Vp-p
60W
2.7Vp-p
62.1W
2.7Vp-p
61W
3.6Vp-p
62.5W
4.6Vp-p
line regulation
load regulation3
±4.0%
±10%
±4.0%
±10%
±4.0%
±10%
±4.0%
±10%
±4.0%
±10%
±4.0%
±10%
±4.0%
±10%
efficiency
DC voltage adj.6
input voltage range5
83%
11~13V
90~264VAC
84.5%
13.8~16.2V
86.5%
18~22V
86.5%
22~26V
87%
25~30V
87%
32.5~39V
88%
43.6~51.8V
frequency range
current adj. range6
47~63 Hz
3%~-25%
AC input current
0.8A/115VAC; 0.4A/230VAC
inrush current
40A/230VAC
leakage current
0.5mA/240VAC
overload protection
shortcircuit protection4
95%-110% 130% (max) type: constant current limiting, recovers automatically after fault removal
hiccup mode, recovers automatically after fault condition is removed
over voltage protection
13.8~16V
17.5~21V
22.8~25V
28~32V
31~35V
41~46V
54~60V
type: shut down o/p voltage, recovers automatically after temperature goes down
over temp. protection
95°C ±10°C (TSW1) detect on heatsink of power transistor type: shutdown o/p voltage, recovers
automatically after fault removal
temperature coefficient
±0.03% / °C (0~50°C)
set up, rise, hold up time
1500ms, 100ms / 230VAC, 300ms, 100ms / 115VAC at full load
vibration
10~500Hz, 2G 10min./1 cycle (1 hour each axes)
withstand voltage
I/P-O/P: 4.25KVAC,
isolation resistance
I/P-O/P, 500VDC / 100M Ohms min.
working temp., humidity
-30°C~+50°C (refer to output derating curve), 20%-90% RH
storage temp., humidity
-40°C~+80°C, 10-95% RH
MTBF
497.8Khrs/min at full load 25°C MIL-HDBK-217F
safety standards
UL1310 Class 2,CAN/CSA C22.2 NO. 223-M91(except for 48V), EN61347-1, EN61347-2-13, IP64 Approved
EMC standards
CISPR11 (EN55011), CISPR22 (EN55022) class B, EN61000-3-2,3, EN61000-4,2,3,4,5,6,8,11,
ENV50204, EN55024, EN61547 (light industrial level, criteria A)
Notes:
1. all parameters NOT specifically mentioned are measured at 230Vac input, rated load, 25°C ambient
2. ripple & noise are measured at 20MHz by using a 12” twisted pair terminated with a 0.1μF & 47 μF capacitor
3. tolerance includes set up tolerance, line regulation, load regulation
4. please refer to OLP characteristics.
5. derating may be needed under low input voltage. Please check the derating curve for more details
6. output voltage can be adjusted through the SVR1 on the PCB; limit of output constant current level can be adjusted through the SVR2 on the PCB
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382