English
Language : 

VPD-45B Datasheet, PDF (1/2 Pages) CUI INC – 45W 1~3 Output Switching Supply
•
VPD-45B 45W 1~3 Output Switching Supply
Features
·Universal AC input/Full range
·Low leakage current<0.5mA
·Protections:Short circuit/Over load/Over voltage
·Cooling by free air convection
·100% full load burn-in test
·Fixed switching frequency at 65KHz
·2 year warranty
DC output voltage
Output V. tolerance
Output rated current
Output current range
Ripple & noise
Line regulation
Load regulation
DC output power
Maximum output power
Efficiency
DC voltage adj.
Input voltage range
AC current
Inrush current
Leakage current
Overload protection
Temperature coefficient
Set up, rise, hold up time
Vibration
Withstand voltage
Isolation resistance
Working temp., humidity
Storage temp., humidity
Dimensions
Weight
Safety standards
EMC standards
CH1
CH2
5V
24V
±4%
±7%
3.2A
1.2A
0.4-5A
0.2-1.8A
50mVp-p
150mVp-p
±1%
±2%
±3%
±4%
65.5W
Rated output power for convection; 72W with 18 CFM min.
78%
CH1:+10,-5%
90~264VAC 47~440Hz ; 120~370VDC
1A/115V 0.7A/230V
cold start 20A/115V 40A/230V
<0.5mA
53~75W output power
type: Hiccup mode, recovers automatically after fault condition is removed
±0.04% / ºC (0~50ºC) ON +5V output
800ms, 20ms, 20ms
10~500Hz, 2G 10 min./1 cycle, period of 60 min. each axes
I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC, for 1 min.
I/P-O/P, I/P-FG, O/P-FG: 500VDC / 100M Ohms min.
-10°C~+60% (refer to output derating curve), 20%-90% RH
-20°C~+85°C, 10%-95% RH
5x3 x1.1 inches (127x76.2x28 mm)
0.44 lb. (0.2 Kgs)
UL1950, TUV EN60950
CISPR22 (EN55022), IEC1000-4-2,3,4,5 IEC1000-3-2,3
Notes:
1. All parameters are specified at 230VAC input, rated load, 25°C 70% RH ambient
2. Tolerance includes set up tolerance, line regulation, load regulation
3. Ripple & noise are measured at 20MHz by using a 12” twisted pair terminated with a 0.1uF & 47 uF capacitor
4. Line regulation is measured from low line to high line at rated load
5. Output provided up to maximum current, but related to maximum output power
6. Each output provide up to maximum current, but total load cannot exceed max. output power
7. Mounting holes M1 and M2 should be grounded for purposes
*V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise cus-
tomers to verify the most up-to-date product information before placing orders. V-Infinity assumes no liability or responsibility for cus-
tomer’s applications using V-Infinity products other than repair or replacing (at V-I’s option) V-Infinity products not meeting V-I’s pub-
lished specifications. Nothing will be covered outside of standard product warranty.
V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005
www.v-infinity.com 1-866-372-1258