VMS-300 Datasheet, PDF (1/8 Pages) CUI INC – AC-DC POWER SUPPLY | |||
|
For more information, please visit the product page.
SERIES: VMS-300 â DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
⢠up to 3002 W continuous power
⢠12.5 W/in3 power density
⢠universal input (90~264 Vac)
⢠12 Vdc auxiliary fan output
⢠over voltage, short circuit, and over temperature protections
⢠built-in active PFC function
⢠efficiency up to 85%
date 05/05/2016
page 1 of 8
RoHS
MODEL
output
voltage
(Vdc)
output
current
max
(A)
output
power
max
(W)
VMS-300-12
12
252
3002
VMS-300-15
15
202
3002
VMS-300-24
24
12.52
3002
VMS-300-36
36
8.332
3002
VMS-300-48
48
6.252
3002
VMS-300-D0512
V1
5
V2
12
243
13.333
2403
VMS-300-D1224
V1
12
V2
24
13.333
6.673
2403
VMS-300-12-CF
12
25
300
VMS-300-15-CF
15
20
300
VMS-300-24-CF
24
12.5
300
VMS-300-36-CF
36
8.33
300
VMS-300-48-CF
48
6.25
300
VMS-300-D0512-CF
V1
5
V2
12
24
13.33
2403
VMS-300-D1224-CF
V1
12
V2
24
13.33
6.67
2403
VMS-300-12-CFS
12
25
300
VMS-300-15-CFS
15
20
300
VMS-300-24-CFS
24
12.5
300
VMS-300-36-CFS
36
8.33
300
VMS-300-48-CFS
48
6.25
300
VMS-300-D0512-CFS
V1
5
V2
12
24
13.33
2403
VMS-300-D1224-CFS
V1
12
V2
24
13.33
6.67
2403
Notes:
1. Peak power of 600 W within 500 µs only applies to single output models
2. Total continuous output power will not exceed 300 W with 25 CFM forced air, 150 W without fan.
3. Total combined continuous output power will not exceed 240 W with 25 CFM forced air, 120 W without fan.
4. Measured at 10 kHz ~ 20 MHz, with 0.1 µF ceramic and 22 µF electrolytic parallel capacitors
5. 1% minimum load is required to maintain the ripple and regulation (10% for dual output models)
cui.com
ripple and
noise4, 5
max
(mVp-p)
120
150
240
360
480
50
120
120
240
120
150
240
360
480
50
120
120
240
120
150
240
360
480
50
120
120
240
efficiency
min
(%)
82
82
83
84
84
80
85
82
82
83
84
84
80
85
82
82
83
84
84
80
85
|
▷ |