English
Language : 

VHK100W Datasheet, PDF (1/10 Pages) CUI INC – chassis mount dc-dc converter
PART NUMBER: VHK100W
rev.
ppaaggee 1 of 10
ddaattee 08/2009
DESCRIPTION: chassis mount dc-dc converter
description
The VHK100W series of rugged DC-DC
converters are designed for high
reliability applications, featuring integral
heat sink, over-temperature protection,
over-current protection and input
transient voltage protection. With an
external input fuse, the converter can
protect accidental input polarity reversal.
The wide 4:1 input range (10-36V or 18-
75V) is very useful to stabilize an input
source like batteries in various
discharging and charging conditions.
Additionally, high efficiency, fast
response, tight regulations, remote sense
and remote On/Off control make these
converters very useful in many industrial
and communications applications.
features
·66-100W isolated output
·Efficiency to 87%
·RoHS Compliant
·4:1 input range
·Regulated output
·Continuous short circuit
protection
·Metal enclosure with integrated
heatsink
·Rugged design
·Over-temperature shutdown
MODEL
VHK100W-Q24-S3R3
VHK100W-Q24-S5
VHK100W-Q24-S12
VHK100W-Q24-S15
VHK100W-Q24-S24
VHK100W-Q24-S28
VHK100W-Q24-S48
VHK100W-Q48-S3R3
VHK100W-Q48-S5
VHK100W-Q48-S12
VHK100W-Q48-S15
VHK100W-Q48-S24
VHK100W-Q48-S28
VHK100W-Q48-S48
input voltage
nominal
range
(V dc)
(V dc)
24
9.0~36.0
24
9.0~36.0
24
9.0~36.0
24
9.0~36.0
24
9.0~36.0
24
9.0~36.0
24
9.0~36.0
48
18.0~75.0
48
18.0~75.0
48
18.0~75.0
48
18.0~75.0
48
18.0~75.0
48
18.0~75.0
48
18.0~75.0
output
voltage
(V dc)
3.3
5
12
15
24
28
48
3.3
5
12
15
24
28
48
output
current 1
(A)
20
20
8.3
6.7
4.17
3.57
2.08
20
20
8.3
6.7
4.17
3.57
2.08
input current
no load2
full load2
(mA)
(mA)
35
3438
35
5081
35
4940
35
4898
35
4905
35
4151
35
4952
50
1741
50
2465
50
2427
50
2421
50
2397
50
4151
50
2447
efficiency
typ.3
(%)
80
82
84
85.5
85
86
84
79
84.5
85.5
86.5
87
86
85
notes:
INPUT
parameter
input voltage range
under voltage lockout
remote on/off control4
input filter
notes:
1. see output derating curves (page 4)
2. input currents are measured at nominal input voltage
3. efficiency is measured at nominal line, full load
conditions/description
min
9
18
24 Vin power up
24 Vin power down
48 Vin power up
48 Vin power down
section 13 in the application notes
PI type
4. add suffix “N” to the model number for negative logic on/off control
nom
24
48
8.8
8
17
16
max
36
75
units
V dc
V dc
V dc
V dc
V dc
V dc
*V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise customers to verify the most up-to-
date product information before placing orders. V-Infinity assumes no liability or responsibility for customer’s applications using V-Infinity products other than repair
or replacing (at V-I’s option) V-Infinity products not meeting V-I’s published specifications. Nothing will be covered outside of standard product warranty.
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383 www.v-infinity.com