English
Language : 

VF-S250-XXA-CF Datasheet, PDF (1/5 Pages) CUI INC – AC-DC POWER SUPPLY
For more information, please visit the product page.
SERIES: VF-S250-XXA-CF │ description: AC-DC POWER SUPPLY
FEATURES
• up to 250 W continuous power
• 600W peak power within 500 µs duty duration
• metal top cover and fan
• passive power factor correction
• power good signal
• remote on/off control
• 3,000 Vac isolation voltage
• over load, over voltage, over temperature, and short circuit protections
• UL, cUL, and TUV 60950-1 safety approvals
• efficiency up to 83%
date 08/13/2013
page 1 of 5
RoHS
MODEL
output
voltage
(Vdc)
output
current
max
(A)
output1
power
max
(W)
ripple and
noise 2,3
max
(mVp-p)
efficiency
typ
(%)
VF-S250-05A-CF
5
40
200
50
75%
VF-S250-09A-CF
9
25
225
90
83%
VF-S250-12A-CF
12
20.83
250
120
80%
VF-S250-15A-CF
15
16.67
250
150
83%
VF-S250-18A-CF
18
13.89
250
180
83%
VF-S250-24A-CF
24
10.42
250
240
83%
VF-S250-28A-CF
28
8.93
250
280
83%
VF-S250-36A-CF
36
6.93
250
360
83%
VF-S250-48A-CF
48
5.21
250
480
83%
VF-S250-54A-CF
54
4.63
250
540
83%
Notes:
1. Maximum power must not exceed 135 W with convection cooling or 250 W for forced air. 5 and 9 V models maximum current listed.
2. 1% minimum load is required to maintain the ripple and regulation.
3. Ripple and noise is measured from 10 KHz to 20 MHz at output terminals with a 0.1 μF ceramic capacitor and a 22 μF electrolytic capacitor in parallel.
PART NUMBER KEY
VF - S250 - XXA - CF - XX
Base Number
Output Voltage
Low leakage option:
“blank” = standard specification
L = low leakage (contact factory)
Input/Output connector:
“blank” = Terminal block input / Terminal block output
1 = Molex input / Molex output
2 = Molex input / Terminal block output
3 = Terminal block input / Molex output
cui.com