English
Language : 

VAT2-S5-D5-SMT_08 Datasheet, PDF (1/3 Pages) CUI INC – dc-dc converter
PART NUMBER: VAT2-SMT series
DESCRIPTION: dc-dc converter
rev.
page 1 of 3
date 02/2008
description
Designed to convert fixed volt-
ages into an isolated voltage, the
VAT2-SMT series is well suited for
providing board-mount local sup-
plies in a wide range of applica-
tions, including mixed analog/digi-
tal circuits, test & measurement
equip., process/machine controls,
datacom/telecom fields, etc...
The semi-regulated output can be
followed by 3-terminal regulators
to provide output protection, in
addition to output regulation.
features
·isolated 2 W output
·temperature range: -40°C~+85°C
·unregulated
·high efficiency to 85%
·dual voltage output
·small footprint
·SMD package style
·industry standard pinout
·UL94-V0 package
·no heatsink required
·1K Vdc isolation
·high power density
·no external component required
·low cost
model
number
VAT2-S5-D5-SMT
VAT2-S5-D9-SMT
VAT2-S5-D12-SMT
VAT2-S5-D15-SMT
VAT2-S12-D5-SMT
VAT2-S12-D9-SMT
VAT2-S12-D12-SMT
VAT2-S12-D15-SMT
input voltage
nominal
range
5 Vdc
4.5~5.5 Vdc
5 Vdc
4.5~5.5 Vdc
5 Vdc
4.5~5.5 Vdc
5 Vdc
4.5~5.5 Vdc
12 Vdc
10.8~13.2 Vdc
12 Vdc
10.8~13.2 Vdc
12 Vdc
10.8~13.2 Vdc
12 Vdc
10.8~13.2 Vdc
output
voltage
±5 Vdc
±9 Vdc
±12 Vdc
±15 Vdc
±5 Vdc
±9 Vdc
±12 Vdc
±15 Vdc
output current
max.
min.
±200 mA
±20 mA
±111 mA
±11 mA
±83 mA
±8 mA
±67 mA
±7 mA
±200 mA
±20 mA
±111 mA
±11 mA
±83 mA
±8 mA
±67 mA
±7 mA
efficiency
82%
83%
84%
82%
83%
84%
84%
85%
OUTPUT SPECIFICATIONS
item
test conditions
output power
line regulation
for Vin change of 1%
load regulation
10% to 100% full load (±5 output)
10% to 100% full load (±9 output)
10% to 100% full load (±12 output)
10% to 100% full load (±15 output)
output voltage accuracy see tolerance envelope graph
temperature drift
@ 100% load
output ripple
20 MHz bandwidth
switching frequency
full load, nominal input
min.
0.2
typ.
12.8
8.3
6.8
6.3
75
70
max.
2
±1.2
15
15
15
15
0.03
150
units
W
%
%
%
%
%
%/°C
mVp-p
KHz
NOTE:
1. All specifications measured at TA=25°C, humidity <75%, nominal input voltage and rated output load unless
otherwise specified.
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382