English
Language : 

FSC-S5_10 Datasheet, PDF (1/3 Pages) CUI INC – ac-dc converter
SERIES: FSC-S5
For more information, please visit the product page.
DESCRIPTION: ac-dc converter
rev.
ppaaggee 1 of 3
ddaattee 04/2010
features
• approved to UL60950, CSA C22.2 NO.60950,
CB(IEC 60950), CE(EN60950)
• universal input 85~264 Vac/ 110~340 VDC
• encapsulated, compact case
• high efficiency
• surface mounting technology
• 100kHz fixed frequency
• fixed output voltage
• thermal shutdown
d • output short circuit protection
• low output ripple and noise
• isolated output
e • 2 year warranty
model
u number
FSC-S5-3R3U
FSC-S5-5U
in FSC-S5-12U
FSC-S5-15U
FSC-S5-24U
input
voltage
AC 85-264V / DC 110-340V
AC 85-264V / DC 110-340V
AC 85-264V / DC 110-340V
AC 85-264V / DC 110-340V
AC 85-264V / DC 110-340V
output
voltage
3.3V @ 1.25A
5V @ 1.0A
12V @ 0.42A
15V @ 0.33A
24V @ 0.21A
t INPUT
parameter
input frequency
n input voltage
input current
o inrush current
c leakage current
conditions/description
output power derated from 85-90 VAC
AC input of 110 VAC
AC input of 220 VAC
measured at 110 VAC at full load, cold start
measured at 220 VAC at full load, cold start
measured at 110 VAC
measured at 220 VAC
is OUTPUT
parameter
voltage tolerance
ripple and noise
D line regulation
conditions/description
power
max.
4.125 W
5.0 W
5.0 W
5.0 W
5.0 W
ripple & noise
max.
80 mVp-p
80 mVp-p
120 mVp-p
150 mVp-p
200 mVp-p
min
nom
max
47 (50~60) 440
85
264
110
340
150
80
20
40
0.5
0.75
units
Hz
VAC
VDC
mA
mA
A
A
mA
mA
min
nom
max
units
-2%
+2%
-1%
+1%
-1%
+1%
efficiency
(%)
71
75
77
77
77
load regulation
-1%
+1%
dynamic load regulation
-3%
+3%
temperature drift
-1%
+1%
rise time
100
mS
hold-up time
10
mS
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383 www.v-infinity.com