English
Language : 

EPA120100-P5-SZ Datasheet, PDF (1/7 Pages) CUI INC – linear adapter
For more information, please visit the product page.
PART NUMBER: EPA120100-P5-SZ
DESCRIPTION: linear adapter
rev.
page 1 of 7
date 10/2008
SPECIFICATIONS
output voltage
rated input voltage
primary rated voltage
primary exciting current
secondary rated voltage & current
temperature rise of primary winding (full load)
insulation resistance
HI-POT test
safety standard
weight
RoHS compliant
test conditions
adapter color
12 V ac at 1000 mA
120 V ac
120 V ac 60 Hz 17 W
30 mA rms max.
no load voltage (max.)
full load voltage (1000 mA)
70°C max. using resistance method
>= 100 M Ohm at 500 Vdc
primary to secondary
primary to secondary
primary winding to secondary winding
primary winding to core
secondary winding to core
UL/cUL
388 g
yes
ambient temp
humidity
case
cord
15.6 V
12 V ±5%
1240 V ac at 2 mA for 1 minute
1600 V ac at 2 mA for 1 second
1600 V ac at 2 mA for 1 second
1600 V ac at 2 mA for 1 second
750 V ac at 2 mA for 1 second
40±2°C
90~95% 96 hours at Full Load
black
black
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383